6 MODBUS support
The device supports the following MODBUS RTU functions:
- 0x01 Read Coils
- 0x03 Read Holding Register
- 0x05 Write Single Coil
- 0x06 Write Single Register
- 0x0F Write Multiple Coils
- 0x10 Write Multiple Registers
6.1
6.2 MODBUS addresses
O.
Address Type
R/W
Description
1
1000
Holding
Reg
R
Transponder code [0]
2
1001
Holding
Reg
R
Transponder code [1]
3
1002
Holding
Reg
R
Transponder code [2]
4
1003
Holding
Reg
R
Transponder code [3]
5
1004
Holding
Reg
R
Transponder code [4]
6
1005
Holding
Reg
R
Device model
7
1006
Holding
Reg
R
Software version
8
1007
Holding
Reg
R
Hardware version
9
1008
Holding
Reg
R
Output state after switching and in Safety mode
10
1009
Holding
Reg
R
Time of communication failure followed by a
transition in to Safety mode
11
1010
Holding
Reg
R
The flag of switching the output operation mode
during a failure (Safety Enable)
12
1011
Holding
Reg
R/W
Output mode:
0 – Inactive
1 – Bistable
2 – Astable
3 – 1 impuls
13
1012
Holding
Reg
R/W
Time of output switching on ( * 100ms)
14
1013
Holding
Reg
R/W
Time of output switching off (*100ms)
15
1000
Single Coil
R/W
Output switching on
16
1001
Single Coil
R/W
Reserve
17
1002
Single Coil
R
Output mode
18
1003
Single Coil
R
Reserve
19
1004
Single Coil
R/W
Reading flag
Reading: 1 – read a new transponder