3 Safety guidelines

The module has been constructed using modern electronic components, according to the latest 
trends in the global electronics. 

3.1

Power supply

The module is adapted to supply DC 10-24V.

3.2

Storage, working environment and transportation 

The module has to be used in closed environments free from fumes and corrosive atmosphere. 
Environmental conditions for storage:

temperature from + 5°C to +45°C,

relative humidity does not exceed 75%,

atmospheric pressure is in the range 700 – 1060hPa.

Environmental conditions for use: 

temperature from  +10°C to +30°C,

relative humidity from 30% to 75%,

atmospheric pressure is in the range 700 – 1060hPa.

Recommended conditions for transportation:

temperature from -10°C to +45°C,

humidity from 20 to 95%,

atmospheric pressure is in the range 700 – 1060hPa.

3.3

Installation and use of the module

The module should be used following the guidelines shown in next part of the user manual. 

3.4

Utilisation of the modulea

When it becomes necessary to liquidate the device (e.g., after the time of use), please contact the 
manufacturer or its representative, who are obliged to respond appropriately, i.e., collecting the 
module from the user. You can also ask the companies involved in utilization and / or liquidation of 
electrical or computer equipment. Under no circumstances should you place the device along with 
other garbage.

Summary of Contents for RFID-MB-10

Page 1: ...User manual RFID MODBUS Reader RFID MB 10 INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 785552252 www inveo com pl info inveo com pl...

Page 2: ...priate ways of dealing with this device the basic principles of safety and maintenance Please also keep the user manual so that you can read it during later use Remember The manufacturer is not liable...

Page 3: ...ILISATION OF THE MODULEA 5 4 CONSTRUCTION EQUIPMENT 6 4 1 GENERAL FEATURES 6 5 DEVICE CONFIGURATION 7 5 1 OUT MODE 7 5 2 OUTPUT CONTROL OUT STATE TEST 8 5 3 READING CARD NUMBER CARD SERIAL NUMBER 8 5...

Page 4: ...ct of guarantee if the following conditions are met all repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply network installation meets...

Page 5: ...midity from 30 to 75 atmospheric pressure is in the range 700 1060hPa Recommended conditions for transportation temperature from 10 C to 45 C humidity from 20 to 95 atmospheric pressure is in the rang...

Page 6: ...15mA 12V Transponders Supported transponders UNIQUE Carrier frequency 125kHz Coding Manchester Reading distance 10cm Communication 1 port compatible with RS485 USB port for configuration Support MODBU...

Page 7: ...ot required the device is fed through the USB port Drawing 1 Aplication window 5 1 OUT mode Mode Set the output mode selected from Static bistable mode Toggle momentary mode alternately turning on and...

Page 8: ...hows the last read transponder code 5 4 RS485 Configuration of transmission RS485 The field is used to configure the device communication MODE setting 9 bit transmission None Odd Even Mark bit 1 the s...

Page 9: ...R Software version 8 1007 Holding Reg R Hardware version 9 1008 Holding Reg R Output state after switching and in Safety mode 10 1009 Holding Reg R Time of communication failure followed by a transit...

Page 10: ...04 appear random data Correct number shows only in the moment of reading new event indicated by setting the registry Single Coil 1004 1 read a new transponder The next reading of the transponder is on...

Page 11: ...elay output max 1 A when 30 VDC max 0 5 A when 125 VAC RS485 Communication port Power LED LED indicates power connection to the module Status LED LED indicates operation of the relay USB USB port modu...

Page 12: ...Notes...

Page 13: ......

Reviews: