2 Device description 

NANO   TEMP   module   is   used   to   read   temperature   over   different   LAN   protocols.   The
temperature readout is possible using built in www website, HTTP GET protocol, Modbus
TCP, SNMP. This module can communicate with other Inveo modules and trigger relay
actions 

3 Warranty and liability of the manufacturer 

The   manufacturer   provides a   2-year warranty   on the   module.   The   manufacturer   also
provides post-warranty service for 10 years from the date of the introducing the module
on   the   market. The   warranty covers   all defects   in   material and   workmanship.

The manufacturer undertakes to comply with the contract of guarantee, if the following
conditions are met:

All repairs,   alterations,   extensions and device calibrations are   performed by   the
manufacturer or authorized service,

supply network installation meets applicable standards in this regard,

device is operated in accordance with the recommendations outlined in this manual,

device is used as intended.

The   manufacturer assumes   no   responsibility for   consequences resulting   from improper
installation, improper use of the module, not following this manual and the repairs of the
module by individuals without permission.

This device doesn’t contain serviceable parts. The repairs can be done only by
manufacturers approved repair service.

User manuald NANO TEMP                      

                       

Page 

5

 of 

21

Summary of Contents for NANO TEMP

Page 1: ...User manual Temperature reading module NANO TEMP Soft 1 05 INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 33 444 65 87 www inveo com pl info inveo com pl...

Page 2: ...aking into account the basic principles of safety and maintenance Please also keep the user guide that you can use it during subsequent use Manufacturer Liability The manufacturer is not liable for an...

Page 3: ...TION 8 6 1 CHANGING THE PC SETTING FOR MODULE CONFIGURATION 8 6 2 CONFIGURATION OF THE MODULE MODULE THROUGH WEB BROWSER 9 6 3 INPUT READOUT 10 6 4 ACCESS CONFIGURATION 11 6 5 SNMP CONFIGURATION 13 6...

Page 4: ...and important information Failure to follow warnings could cause injury or damage to the module Important information and guidelines Following this guidelines makes the use of the module easier Attent...

Page 5: ...manufacturer undertakes to comply with the contract of guarantee if the following conditions are met All repairs alterations extensions and device calibrations are performed by the manufacturer or au...

Page 6: ...ic pressure 700 1060hPa Environmental conditions for use Temperature 10 C to 30 C Relative humidity 30 to 75 Atmospheric pressure 700 to 1060hPa Recommended conditions for transportation Temperature 1...

Page 7: ...ation protocol available for user NANO module is equipped with two LEDs indicators power and moment that temperature is read 5 2 Technical specification Power supply voltage 10 24VDC POE Power consump...

Page 8: ...tart Control Panel Network connections Then right click on the current network connection and click Properties The configuration screen as shown below should be visible on the screen Choose the Intern...

Page 9: ...admin00 There are several fields used to configure the module network settings MAC Address MAC address of the module Host Name NETBIOS host name of the module Enable DHCP When this box is ticked the m...

Page 10: ...the module will connect to optional Destination Port Network port of the server that the module can connect to After changing the configuration press the Save Config button 6 3 Input readout Visualisa...

Page 11: ...then press Save Config to save new passwords Enabling disabling particular service This function enables disables different services By enabling the tick box next to a service user can turn it on or o...

Page 12: ...rotocol Enable SNMP enables disables access using SNMP protocol Enable Destination client enables disables access using mode of operation customer Enable TFTP bootloader enables disables 10 second boo...

Page 13: ...protocol enables user to retrieve and set the output status and to read state of inputs and counters The MIB file describing the structure can be downloaded the SNMP tab NANO TEMP module can send TRA...

Page 14: ...e at IP address 192 168 111 15 and port 9761 TCPRel in 1 host 192 168 111 15 port 9761 readtemp 6 7 Managing the module using Linux command line software The module can be configured using Linux comma...

Page 15: ...S TCP Holding Registers Register Name Mode R read W write Description 4000 ThermostatL R W Thermostat low setting 4001 ThermostatH R W Thermostat high setting 4002 Alarm mode R W 1 OFF disabled 2 Lowe...

Page 16: ...out on 00000000 on in 00000000 in counter1 0 counter1 temp1 21 3 temp1 response Section Description prod_name PE DS prod_name Type of module In this case PE_DS out 00000000 out Output state enabled d...

Page 17: ...3 24 31 CRC WWW control 15 99 x 1 status 0x55 off all other on x x x x x x CRC ON or NO Read channels 15 100 x x x x x x x x CRC CH7 CH0 Chx 2 bytes 1 output state 2 coil state Read channel name 15 10...

Page 18: ...6 Data 7 CRC 15 10 1 100 0 0 0 0 0 0 132 6 11 Communication with module from outside network If the module is in the LAN network different than PC that connects to it the redirection of ports is nece...

Page 19: ...button 8 Restoring factory defaults In order to restore the module to its factory defaults press and hold reset button for at least 10 15 seconds The green LED will start flashing 4 times second With...

Page 20: ...for duration of programming To perform the programming operation go to the Windows command line Start Run type cmd and confirm with Enter Then navigate to the directory where the file resides and ent...

Page 21: ...Notes...