51
Index1:
1:Indoor or Outdoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must has
problems and need to be replaced.
DC motor voltage input and output
NO.
Color
Signal
Voltage
1
Red
Vs/Vm
280V~380V
2
---
---
---
3
Black
GND
0V
4
White
Vcc
14-17.5V
5
Yellow
Vsp
0~5.6V
6
Blue
FG
14-17.5V
2. Outdoor DC Fan Motor (control chip is in outdoor PCB)
Power on ,and check if the fan can run normally, if the fan can run normally, the PCB must has
problems and need to be replaced, If the fan can
’t run normally, measure the resistance of each two
pins. If the resistance is not equal to each other, the fan motor must have problems and need to be
replaced, otherwise the PCB must has problems and need to be replaced.
3. Indoor AC Fan Motor
Power on and set the unit running in fan mode at high fan speed. After running for 15 seconds,
measure the voltage of pin1 and pin2. If the value of the voltage is less than 100V(208~240V power
supply)or 50V(115V power supply), the PCB must has problems and need to be replaced.
Summary of Contents for P7MVI-09WiFi
Page 8: ...8 For P7MVI 09WIFI...
Page 9: ...9 For P7MVI 12WIFI For P7MVI 18WIFI...
Page 10: ...10 For P7MVI 24WIFI...
Page 11: ...11 3 2 Outdoor Unit...
Page 14: ...14 For P7MVO 24...
Page 16: ...16 P7MVO 09 P7MVO 12 16022000020169...
Page 17: ...17 P7MVO 18 P7MVO 24...
Page 18: ...18...
Page 25: ...25 cap to a torque of 18N m Be sure to check for gas leakage...