38
TECHNICAL DATA
38
iV-Smart+ ventilation unit | Installation instructions
5.3
Specifications according to ErP Directive, Regulation 1254/2014
iV-Smart+ ventilation unit, demand-controlled:
iV-Smart+ product data sheet according to
EU Ordinance 1254/2014 dated 11 July 2014
Pt
Description
Values
a
Supplier
inVENTer GmbH
b
Model identifier
iV-Smart+, iV-Smart+ Corner,
iV-Smart+ Nordic
iV-Smart+ Sylt, iV-Smart+ Top
c
SEC class / Specific Energy Con
-
sumption (SEC) [kWh/(m²a)]
Cold
-88.068
Average
A+
-43.952
Warm
-18.678
d
Ventilation type
BVU
e
Type of drive
2
f
Type of heat recovery system
Regenerative
g
Degree of temperature change ƞt [%]
87
h
Maximum air flow rate [m³/h]
58
i
Electrical input power (incl. control) [W]
6
j
Sound power level Lwa [dB (A)]
45
k
Reference air flow [m³/h]
42
l
Reference pressure difference [Pa]
0
m
SEL [W/m³/h]
0.15
n
Control factor
0.65
o
Internal and external transfer [%]
n. a.
p
Mixing quota [%]
n. a.
q
Position and description of the indicator for filter change
Control unit
r
Instructions regarding controllable supply and extract air
grilles on the façade (unidirectional ventilation units only) None
s
Internet address
www.inventer.de
t
Sensitivity to pressure changes [%]
29.4
u
Airtightness between interior and exterior [m
3
/h]
6.3
v
Annual power consumption [kWh/(m²a)]
0.87
w
Annual savings
Heating energy [kWh/(m²a)]
Cold
90.25
Average
46.13
Warm
20.86