Invacare Platinum IRC10LX Operator'S Manual Download Page 18

REGISTER YOUR PRODUCT!

The benefits of registering:

1.

Safeguard your investment.

2.

Ensure long term maintenance and servicing of your purchase.

3.

Receive updates with product information, maintenance tips, and industry
news.

4.

Invacare can contact you or your provider, if servicing is needed on your
product.

5.

It will enable Invacare to improve product designs based on your input
and needs.

Register ONLINE at www.invacare.com

- or -

Complete form and mail.

Any registration information you submit will be used by Invacare Corporation

only, and protected as required by applicable laws and regulations.

NAME _____________________________________________________

ADDRESS __________________________________________________

CITY _______________________ STATE/PROVINCE _____________

ZIP/POSTAL CODE ________________

EMAIL ___________________________     PHONE NO. ____________

INVACARE MODEL NO. _____________________________________

SERIAL NO. ______________________

PURCHASED FROM _______________

DATE OF PURCHASE: _____________

PRODUCT REGISTRATION FORM

Summary of Contents for Platinum IRC10LX

Page 1: ...Operator s Manual For more information regarding Invacare products parts and services please visit www invacare com Platinum Series XL 5 10 Oxygen Concentrators Standard with SensO2 and HomeFill II I...

Page 2: ...are many different types of humidifiers oxygen tubing cannulas and masks that can be used with this device You should contact your local home care provider for recommendations on which of these devic...

Page 3: ...a Location 21 Recommended Guidelines for Optimum Performance 22 Plug in Power Cord 22 Connect Humidifier If So Prescribed 22 Power Switch 25 Flowrate 26 SensO2 Oxygen Purity Indicator If Your Unit Fe...

Page 4: ...ials that normally would not burn are easily ignited and burn with great intensity in oxygen enriched air Failure to observe this warning can result in severe fire property damage and cause physical i...

Page 5: ...ructions and any additional instructional material such as Owner s Manuals Service Manuals or Instruction Sheets supplied with this product or optional equipment If you are unable to understand the Wa...

Page 6: ...roperly if it has been dropped or damaged or dropped into water call qualified technician for examination and repair Keep the cord away from heated or hot surfaces DO NOT move or relocate concentrator...

Page 7: ...ON FIRE OR INJURY TO PERSONS Avoid using while bathing If continuous usage is required by the physician s prescription The concentrator MUST be located in another room at least seven 7 feet from the b...

Page 8: ...rcumstances oxygen therapy can be hazardous Invacare recommends that you seek medical advice before using this machine This equipment is to be used as an oxygen supplement and is not considered life s...

Page 9: ...midifier Flowmeter Accessory IRCPF16 Venture HomeFill II home oxygen compressor IOH200 Outlet Fitting Power Cord NOTE This outlet fitting is to be used only for filling oxygen cylinders with the Ventu...

Page 10: ...for any obvious damage to the carton or its contents If damage is evident notify the carrier or your local dealer 2 Remove all loose packing from the carton 3 Carefully remove all the components from...

Page 11: ...dB Average Altitude Platinum 5 and XL Up to 6 000 ft 1828 meters above sea level without degradation of concentration levels From 6 000 ft 1828 meters to 13 129 ft 4000 meters below 90 efficiency Pla...

Page 12: ...min to 1 L min Rapid Audible Alarm Beeping No Accessories Connected Average Power Consumption Platinum 5 and XL 400W Platinum 10 585W Pressure Relief Mechanism Operational at 35 psi 3 5 psi 241 kPa 24...

Page 13: ...t Platinum 5 and XL 52 lbs 2 lbs 23 6 kg 1 kg Platinum 10 53 lbs 2 lbs 24 0 kg 1 kg Shipping Weight Platinum 5 and XL 58 lbs 2 lbs 26 3 kg 1 kg Platinum 10 60 lbs 2 lbs 27 2 kg 1 kg Operating Ambient...

Page 14: ...rfaces Tubing 7 ft cannula with a maximum 50 ft of Crush Proof Tubing DO NOT pinch Platinum 10 Recommended use up to 25 ft high flow tubing with high flow cannula at all flow rates Relative Humidity 2...

Page 15: ...NOTES Part No 1118353 15 Platinum Series NOTES...

Page 16: ...NOTES Platinum Series 16 Part No 1118353 NOTES...

Page 17: ...Please Seal with Tape Before Mailing...

Page 18: ...com or Complete form and mail Any registration information you submit will be used by Invacare Corporation only and protected as required by applicable laws and regulations NAME _____________________...

Page 19: ...and we will send you information by email and or mail about any available Invacare products that may help treat care for or manage such condition s ____________________________________________________...

Page 20: ......

Page 21: ...concentrator He She should be contacted with any questions or problems regarding your oxygen concentrator This owner s manual will tell you about your concentrator and will serve as a reference as yo...

Page 22: ...erature 50 F 95 F 10 C 35 C Electrical No extension cords Placement No closer than three 3 inches from the wall furniture draperies or similar surfaces Tubing and Cannula 7 ft cannula with a maximum 5...

Page 23: ...he oxygen input and output connections Water from the humidifier bottle will travel through the cannula back to the patient FIGURE 5 1 Filling the Humidifier 2 Place the humidifier bottle in the humid...

Page 24: ...ing the wing nut on the humidifier bottle counterclockwise until it is securely fastened Refer to Detail C in FIGURE 5 3 FIGURE 5 3 Attaching the Humidifier Bottle Adapter 6 Attach oxygen tubing from...

Page 25: ...oncentrator be on and running for a minimum of 30 minutes at a time Shorter periods of operation may reduce maximum product life Power Switch NOTE For this procedure refer to FIGURE 5 5 1 Press power...

Page 26: ...o the line Now center the ball on the L min line prescribed 2 If the flowrate on the flowmeter ever falls below 0 5 L min for Platinum 5 1 L min for Platinum 10 for more than about one minute the LOW...

Page 27: ...the GREEN light will come on SYSTEM OK O2 greater than 85 After five 5 minutes the oxygen sensor will be operating normally and will control the indicator lights depending on oxygen concentration val...

Page 28: ...ocedure refer to FIGURE 5 8 LX models indicator Light Explanation RED light Total Unit Shut Down Switch immediately to a back up oxygen supply Call supplier IMMEDIATELY GREEN light I O On Off System o...

Page 29: ...ines Refer to Preventive Maintenance Record on page 31 Routine Maintenance NOTE The following routine maintenance should be performed more frequently See recommended intervals in each section and prev...

Page 30: ...ith a mild household cleaner and non abrasive cloth or sponge Humidifier NOTE To clean the oxygen humidifier follow the instructions provided by the manufacturer If none are provided follow these step...

Page 31: ...Cabinet Filter s Check Prescribed L min Flow Rate EVERY 180 DAYS FOR IRC5LX EVERY 90 DAYS FOR IRC10LX Check Oxygen Concentration UNITS WITHOUT SensO 2 ANNUALLY DURING PREVENTIVE MAINTENANCE SCHEDULE O...

Page 32: ...OT operating power switch ON 2 No power at outlet 3 Call Service Provider Beep Beep 3 Tripped circuit breaker Alarm CONTINUOUS Concentrator NOT operating Power Switch ON Beeeeeeeep System Failure 1 Un...

Page 33: ...required 1 Clean or Replace filters 2 Inspect for kinks or block ages Correct clean or replace item Once cor rected turn power OFF for 60 seconds and then turn power back ON 3 Check flowmeter is set...

Page 34: ...Flowmeter set at 0 5 L min for Platinum 5 and 1 L min for Platinum 10 or less 1a Inspect for kinks or blockages Correct clean or replace item Once corrected turn power OFF for 60 seconds and then turn...