EN-V233 – 5005 – AA Installation and use of built-in Visio call panel EEN-PIVIV3GB  

Page 1 / 12 

INSTALLATION AND CONNECTION OF 

THE BUILT-IN VISIO CALL PANEL 

 
 

 GENERAL POINTS 

 
The built-in Visio call panel (ref.: EEN-PIVIV3GB) a multifunctional call panel which 
transmits an image of the visitor to the tenant's telephone. 
This call panel is available in a "Stainless-steel" coloured finish and is flush-mounted. It is 
configured using the following website: www.intratone.com in the "management 
website" tab
 
 
It must be connected to the following "real-time" central units

  2 to 4 doors  (ref.: EEN-CEN12) 
  1 door  

(ref.: EEN- CIC12)  

 
Ideal for installation near an entrance gate; four opening methods are possible: 

  By using an authorised fob 
  By typing in a specific trade code 
  By calling a tenant using the call panel, who then opens the door using a key on 

his/her telephone. 

  Using a "mobilekey". 

 
You can select the tenant to call just by entering his/her flat number on the keypad or by 
pressing the arrows. 
 
Product description: 
The Visio intercom with scrolling name-display consists of: 

  A 12-key keypad and backlit LCD screen  
  Two scrolling keys and one call button 
  A square proximity reader. 
  A miniature camera for use in video calls 
  Built-in speech synthesiser: "Call in progress"; "Door open", etc. 

 
                                               

                      

 

+

Screws  
X 6 

+

LCD display 

Proximity reader 

Keys on Keypad 

Scrolling keys 

Call buttons 

Built-in wall 

box 

Cancel key 

Trade key 

Summary of Contents for EEN-PIVIV3GB

Page 1: ...ef EEN CIC12 Ideal for installation near an entrance gate four opening methods are possible By using an authorised fob By typing in a specific trade code By calling a tenant using the call panel who then opens the door using a key on his her telephone Using a mobilekey You can select the tenant to call just by entering his her flat number on the keypad or by pressing the arrows Product description...

Page 2: ...E GATE WITH THE 2 TYPES OF CENTRAL UNITS 6 E SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING 6 EQUIPMENT CONFIGURATION 7 A GENERAL POINTS 7 B CONFIGURATION WITH A TENANTIAL CENTRAL UNIT EEN CEN12 7 C CONFIGURATION WITH AN INTRACODE EEN CIC12 CENTRAL UNIT 8 POST FITTING CHECK 9 D ON THE PANEL 9 E DOOR CONNECTION 9 F CALLS 9 G IN THE CASE OF A FITTING WITH A 3G UNIT 9 H IN THE CASE OF A FITT...

Page 3: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 3 12 DIMENSIONS AND ASSEMBLY A DIMENSIONS OF CALL PANEL ...

Page 4: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 4 12 B BUILT IN BOX DIMENSIONS ...

Page 5: ...nel is installed with a 3G unit AUDIO or VIDEO or B FOR USE IN AUDIO CALLS ONLY Connect the following terminals up to the central unit Terminal Detail NB pair Power supply 1 D D Data 1 A A Audio 1 C FOR USE IN VIDEO CALLS Also connect the following terminals up to the V V VIDEO 1 terminals on the 3G unit Terminal Detail NB pair V V Video 1 EEN CIC12 EEN M3G EEN M3G EEN M3G EEN PIVIV3GB THE CENTRAL...

Page 6: ...NNECTING AN ENTRANCE GATE PLUS A BUILDING It is mandatory to use an EEN CEN12 central unit with in this example an extension board Scenario Audio and Video calls from the entrance gate Only Audio calls can be made from the building entrance 4 2 6 6 6 Add an extension card doors 3 and 6 6 2 2 2 In this example door 4 remains available 41 49 and CRT Connections in red refer to Visio V V Connections ...

Page 7: ...nu on the central unit With regard to the volume level you have 2 options in the Panel volume menu Direct selection of volume Enter a value between 1 and 4 corresponding to the sound level Settings on the Panels This menu starts a 15 minute timer During this time you can move between the call panel or panels connected to this central unit in order to adjust the sound level Step 1 Type in the keypa...

Page 8: ...e 09 15 Type winter Numeric keys for time entry Key to select summer winter season Accept remote time YES Key to select YES or NO Door settings Door settings PB NO Opening time 05s Key to select NO or NC Numeric keys for door opening time entry or Key to Exit Key to Validate Volume of call panels Direct selection of the volume Enables direct input via the keypad of the volume of the call panel con...

Page 9: ...t o Audio Call o Video Call Check that during the call the tenant can open the door by pressing the key on his her telephone See Test Procedure in the central unit guide G IN THE CASE OF A FITTING WITH A 3G UNIT If you use a 3G unit with your call panel you can see the signal reception level for the unit by pressing the 2 scrolling arrow keys on the display Depending on the situation you will see ...

Page 10: ... the and or terminals Check cabling between the central unit and the call panel When swiping a badge the green LED on the reader lights up but the door does not open Relay on the central unit not working Cable to the door Check if relay sticks Check cabling between the central unit and the door If the call panel says Call in progress but the tenant cannot hear the visitor Incorrect cabling on the ...

Page 11: ...e telephone network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be placed in the vicinity of other sources of electrical power e g mains power supply Operating warranty The call panel is guaranteed for a temperature range of between 20 C and 70 C and for relative humidity not exceeding 70 End of life product recycling The panel and its accessories ...

Page 12: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 12 12 B CERTIFICATE ...