EN-V233 – 5005 – AA Installation and use of built-in Visio call panel EEN-PIVIV3GB  

Page 9 / 12 

POST-FITTING CHECK 

 
Before leaving the fitting, the following points should be checked: 

D) 

O

N THE 

P

ANEL

 

-  Display shows the welcome message 
-  Check that the keypad keys (0, 1, 2 

9, * and #) work. 

Procedure: 

o

  Press #; the display shows "Call number" 

o

  The numeric keys must be displayed correctly 

o

  Finish using the * key; the display should return to the welcome message. 

-  Check that the keypad keys are backlit. 

 

E) 

D

OOR CONNECTION

 

-  Check door opening with the push button 
-  Check door opening using a badge 

(See Test Procedure in the central unit guide) 

F) 

C

ALLS

 

-   Check the quality of a call by a visitor to a tenant: 

o

  Audio Call 

o

  Video Call 

-  Check that, during the call, the tenant can open the door by pressing the * key on 

his/her telephone 

(See Test Procedure in the central unit guide) 

 

G) 

I

N THE CASE OF A FITTING WITH A 

3G

 UNIT 

 

If you use a 3G unit with your call panel, you can see the signal reception level for the unit 
by pressing the 2 scrolling arrow keys 

  

֠

֠

֠

֠

     on the display.  

 
Depending on the situation, you will see: 
"3G NET Lev 

17

 

3

" or "GSM NET Lev 

17

 

3

 » 

-  NET   : shows that the network has been found by the unit (3G or GSM) 
-  Lev 

: shows the level out of 30 (here,

17

 / 30) and the connection on a scale of 5 

(here 

3

 / 5) 

Press one of the arrow keys to exit from this menu. 
 

H) 

I

N THE CASE OF A FITTING WITH AN 

EEN-CIC12

 CENTRAL UNIT 

 

Remember to make a note of the serial number (7XXXXXX3) of the central unit.  
You will need this to go back into the installation and configure these settings on the 
keypad outside. 
 

 

Summary of Contents for EEN-PIVIV3GB

Page 1: ...ef EEN CIC12 Ideal for installation near an entrance gate four opening methods are possible By using an authorised fob By typing in a specific trade code By calling a tenant using the call panel who then opens the door using a key on his her telephone Using a mobilekey You can select the tenant to call just by entering his her flat number on the keypad or by pressing the arrows Product description...

Page 2: ...E GATE WITH THE 2 TYPES OF CENTRAL UNITS 6 E SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING 6 EQUIPMENT CONFIGURATION 7 A GENERAL POINTS 7 B CONFIGURATION WITH A TENANTIAL CENTRAL UNIT EEN CEN12 7 C CONFIGURATION WITH AN INTRACODE EEN CIC12 CENTRAL UNIT 8 POST FITTING CHECK 9 D ON THE PANEL 9 E DOOR CONNECTION 9 F CALLS 9 G IN THE CASE OF A FITTING WITH A 3G UNIT 9 H IN THE CASE OF A FITT...

Page 3: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 3 12 DIMENSIONS AND ASSEMBLY A DIMENSIONS OF CALL PANEL ...

Page 4: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 4 12 B BUILT IN BOX DIMENSIONS ...

Page 5: ...nel is installed with a 3G unit AUDIO or VIDEO or B FOR USE IN AUDIO CALLS ONLY Connect the following terminals up to the central unit Terminal Detail NB pair Power supply 1 D D Data 1 A A Audio 1 C FOR USE IN VIDEO CALLS Also connect the following terminals up to the V V VIDEO 1 terminals on the 3G unit Terminal Detail NB pair V V Video 1 EEN CIC12 EEN M3G EEN M3G EEN M3G EEN PIVIV3GB THE CENTRAL...

Page 6: ...NNECTING AN ENTRANCE GATE PLUS A BUILDING It is mandatory to use an EEN CEN12 central unit with in this example an extension board Scenario Audio and Video calls from the entrance gate Only Audio calls can be made from the building entrance 4 2 6 6 6 Add an extension card doors 3 and 6 6 2 2 2 In this example door 4 remains available 41 49 and CRT Connections in red refer to Visio V V Connections ...

Page 7: ...nu on the central unit With regard to the volume level you have 2 options in the Panel volume menu Direct selection of volume Enter a value between 1 and 4 corresponding to the sound level Settings on the Panels This menu starts a 15 minute timer During this time you can move between the call panel or panels connected to this central unit in order to adjust the sound level Step 1 Type in the keypa...

Page 8: ...e 09 15 Type winter Numeric keys for time entry Key to select summer winter season Accept remote time YES Key to select YES or NO Door settings Door settings PB NO Opening time 05s Key to select NO or NC Numeric keys for door opening time entry or Key to Exit Key to Validate Volume of call panels Direct selection of the volume Enables direct input via the keypad of the volume of the call panel con...

Page 9: ...t o Audio Call o Video Call Check that during the call the tenant can open the door by pressing the key on his her telephone See Test Procedure in the central unit guide G IN THE CASE OF A FITTING WITH A 3G UNIT If you use a 3G unit with your call panel you can see the signal reception level for the unit by pressing the 2 scrolling arrow keys on the display Depending on the situation you will see ...

Page 10: ... the and or terminals Check cabling between the central unit and the call panel When swiping a badge the green LED on the reader lights up but the door does not open Relay on the central unit not working Cable to the door Check if relay sticks Check cabling between the central unit and the door If the call panel says Call in progress but the tenant cannot hear the visitor Incorrect cabling on the ...

Page 11: ...e telephone network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be placed in the vicinity of other sources of electrical power e g mains power supply Operating warranty The call panel is guaranteed for a temperature range of between 20 C and 70 C and for relative humidity not exceeding 70 End of life product recycling The panel and its accessories ...

Page 12: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3GB Page 12 12 B CERTIFICATE ...

Reviews: