C)

 

Configuration with an Intracode EEN-CIC12 central unit 

 

 

 
 
 

 

 

 

How do I enter settings mode? 

o

  Check that the welcome message is scrolling on the LCD 

o

  Press the 

 

key until the

 "Enter password" 

menu appears. 

o

  Type the serial number of the EEN-CIC12 central unit (7xxxxxx3). 

o

  Validate with the 

 

key

« You are in menu settings mode"

 

To exit settings mode: 

o

  Press the 

 arrow key several times until you return to the scrolling message. 

 

Menu options in settings mode: 

Setting 
the clock

 

 

Date: 28/01/13 
Day: Monday

  

Numeric keys for date entry 
Key

 to select day 

 

 

 


 

Time: 09:15 
Type: winter

  

Numeric keys for time entry 
Key 

 to select summer/winter season 

 

 

 


 

Accept remote 
time: YES

  

Key

 to select YES or NO 

 

 

 

 

Door 
settings 

 

 

Door settings 
PB:NO Opening time: 
05s

 

Key

 to select: NO or NC 

Numeric keys for door-opening time entry 

 

 

 


 

 or 

 

Key 

 to Exit  

Key 

 to Validate 

 

 

 

 

Volume of 
call panels

 

 

Direct selection 
of the volume

 

Enables direct input via the keypad of the 
volume of the call panel connected 

 

 

 

 

INTERNET Update 
Request 

 

Request an Update?  

Key 

 to Validate 

 

 

 

 

Check fitting 

 

Test number:  

Enables direct input of the telephone number 
via the keypad to call for test purposes. 

 

 

 

 

 

 

Start test procedure 

Warning: the "door settings" menu will appear only if switches 4 / 5 / 6 on the EEN-
CIC12 central unit are set to OFF.

 

Entering numbers 

Exit from menus or 
Return to scrolling menu 

Go into menus or Make a 
selection 

Validation  

"Save changes" 

Summary of Contents for EEN-PIVIV3

Page 1: ...ing real time central units 2 to 4 doors ref EEN CEN12 1 door ref EEN CIC12 Ideal for installation near an entrance gate four opening methods are possible By using an authorised badge By typing in a specific code By calling a resident using the call panel who then opens the cabinet using a key on his her telephone Using a mobilekey Product description The Visio telephone intercom with scrolling na...

Page 2: ...GATE WITH THE 2 TYPES OF CENTRAL UNITS 6 E SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING 6 EQUIPMENT CONFIGURATION 7 A GENERAL POINTS 7 B CONFIGURATION WITH A RESIDENTIAL CENTRAL UNIT EEN CEN12 7 C CONFIGURATION WITH AN INTRACODE EEN CIC12 CENTRAL UNIT 8 POST FITTING CHECK 9 D ON THE PANEL 9 E DOOR CONNECTION 9 F CALLS 9 G IN THE CASE OF A FITTING WITH A 3G UNIT 9 H IN THE CASE OF A FITT...

Page 3: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3 Page 3 12 Dimensions and assembly A Dimensions of call panel ...

Page 4: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3 Page 4 12 B Built in box dimensions ...

Page 5: ... call panel is installed with a PSTN line only audio will work AUDIO or VIDEO or B For use in AUDIO calls only Connect the following terminals up to the central unit Terminal Detail NB pair Power supply 1 D D Data 1 A A Audio 1 C For use in VIDEO calls Also connect the following terminals up to the V V VIDEO 1 terminals on the 3G unit Terminal Detail NB pair V V Video 1 EEN CIC12 EEN M3G EEN M3G E...

Page 6: ...ing an entrance gate plus a building It is mandatory to use an EEN CEN12 central unit with in this example an extension board Scenario Audio and Video calls from the entrance gate Only Audio calls can be made from the building entrance 4 2 6 6 6 Add an extension board doors 3 and 4 6 6 2 2 2 In this example door 4 remains available 41 49 and CRT Connections in red refer to Visio V V Connections in...

Page 7: ...nu on the central unit With regard to the volume level you have 2 options in the Panel volume menu Direct selection of volume Enter a value between 1 and 4 corresponding to the sound level Settings on the Panels This menu starts a 15 minute timer During this time you can move between the call panel or panels connected to this central unit in order to adjust the sound level Step 1 Type in the keypa...

Page 8: ... 09 15 Type winter Numeric keys for time entry Key to select summer winter season Accept remote time YES Key to select YES or NO Door settings Door settings PB NO Opening time 05s Key to select NO or NC Numeric keys for door opening time entry or Key to Exit Key to Validate Volume of call panels Direct selection of the volume Enables direct input via the keypad of the volume of the call panel conn...

Page 9: ... o Audio Call o Video Call Check that during the call the resident can open the door by pressing the key on his her telephone See Test Procedure in the central unit guide G In the case of a fitting with a 3G unit If you use a 3G unit with your call panel you can see the signal reception level for the unit by pressing the 2 scrolling arrow keys on the display Depending on the situation you will see...

Page 10: ...e and or terminals Check cabling between the central unit and the call panel When swiping a badge the green LED on the reader lights up but the door does not open Relay on the central unit not working Cable to the door Check if relay sticks Check cabling between the central unit and the door If the call panel says Call in progress but the resident cannot hear the visitor Incorrect cabling on the A...

Page 11: ... telephone network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be placed in the vicinity of other sources of electrical power e g mains power supply Operating warranty The call panel is guaranteed for a temperature range of between 20 C and 70 C and for relative humidity not exceeding 70 End of life product recycling The panel and its accessories m...

Page 12: ...EN V233 5005 AA Installation and use of built in Visio call panel EEN PIVIV3 Page 12 12 B Certificate ...