EN-V233
– 5005 – AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 6 / 12
D)
Scenario of connecting an entrance gate with the 2 types of central units
Connections in red refer to video (V+ / V-)
Connections in black refer to (+ / - and D+ / D- and A+ / A-)
E)
Scenario of connecting an entrance gate plus a building
It is mandatory to use an EEN-CEN12 central unit with, in this example, an extension board.
Scenario:
"Audio and Video" calls from the entrance gate
Only "Audio" calls can be made from the building entrance.
/ 4
/2
/ 6
/ 6
/ 6
Add an extension board - doors 3
and 4
/ 6
/ 6
/ 2
/ 2
/ 2
In this example, door 4 remains available
[41
49 and CRT]
Connections in red refer to Visio (V+ / V-)
Connections in black refer to (+ / - and D+ / D- and A+ / A-)
Extension board
Entrance
gate
Building