7. For sensor end support with sealing plug 
only:Seal the thread of the sealing plug with a 
suitable sealing compound (e.g. PTFE tape). Screw 
the sealing plug into the sensor end support and 
tighten it firmly.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 12a 
 
8. Perform the installation of the sensor into the pipe 
according to the instructions given in chapter 6.1. 

 

6.3  Installation of Type IBF-25 

1. Drill a hole of 35mm diameter into the pipe. 

 

The subsequent Stepps correspond to the installation 
of the  ITABAR sensor type IBF-20 !

 

 

Oberserve the H- dimension during the welding! 
(see also Fig. 9)  

 

6.4  Installation of Type IBF-26 

1. Drill a hole of 35mm diameter into the pipe. 

 

The subsequent Stepps correspond to the installation 
of the  ITABAR sensor type IBF-21 !

 

 
 

Oberserve the H- dimension during the welding! 
(see also Fig. 9)  

 

6.5  Installation of Type IBF-35 

1. Drill a hole of 40mm diameter into the pipe. 

 

The subsequent Stepps correspond to the installation 
of the  ITABAR sensor type IBF-20 !

 

 

Oberserve the H- dimension during the welding! 
(see also Fig. 9)  

 

6.6  Installation of Type IBF-36 

1. Drill a hole of 40mm diameter into the pipe. 

 

The subsequent Stepps correspond to the installation 
of the  ITABAR sensor type IBF-21 !

 

 

Oberserve the H- dimension during the welding! 
(see also Fig. 9)  

 

6.7  Installation of Type IBF-65 

1. Drill a hole of 60mm diameter into the pipe. 

 

The subsequent Stepps correspond to the installation 
of the  ITABAR sensor type IBF-20 !

 

 

Oberserve the H- dimension during the welding! 
(see also Fig. 9)  
 
 

6.8  Installation of Type IBF-66 

The design of the ITABAR sensor of the type IBF-
66 is almost identical to the type IBF-21. The only 
difference is the sensor end support (delivered in 
two pieces). After successful installation of the end 
support, the end cap must be weld onto the end 
support.  
 
1. Drill a hole of 60mm diameter into the pipe. 

 

The subsequent Stepps correspond to the installation 
of the  ITABAR sensor type IBF-21 !

 

 

Oberserve the H- dimension during the welding! 
(see also Fig. 9) 

 

Note ! 

On long sensors, an installation aid can be screwed 
into the ½” thread of the sensor end (e.g. threaded 
pipe). This will make it easier to insert the sensor 
into the opening of the sensor end support and  align 
the sensor. 
 
 

7.  Installation of the Attachments and the 

 

 

p-Transmitter 

7.1 Instrument 

valves 

The instrument valves for the differential pressure 
lines are pre- installed by the manufacturer, if it is 
part of the order. 

Summary of Contents for Itabar IBF

Page 1: ...Installation of the ITABAR Sensor 6 7 Installation of the Attachments and the Dp transmitter 8 8 Measurement Start Up 9 9 Preventive Maintenance 9 10 Trouble Shooting 9 INTRA AUTOMATION GmbH Me und R...

Page 2: ...ns ITABAR Flow sensors type IBF can be used under the following conditions Operating pressure max 320 bar Operating temperature 50 C to 1000 C Nominal Pipe Diameters DN 40 to DN 12000 The sensor mater...

Page 3: ...low measurements of liquids the ITABAR sensor must be installed in the lower half of the pipe circumference the connections to the instruments have to be located below the pipe axis This way gas or ai...

Page 4: ...hysical principles Its design incorporates no moving parts which are subject to wear Fig 6 The sensor is not affected by being slightly out of alignment The influence on the accuracy of the measuremen...

Page 5: ...ion of the most advantageous installation location As a general rule regulating valves throttle valves and gate type valves should be installed behind the sensor NOTE If the recommended straight pipe...

Page 6: ...flow direction Tighten the bolts and nuts Note On flanges with eight bolt holes the welding stud must be welded on so that the bolt holes in the flange form an angle of 22 5 with the pipe axis see Fi...

Page 7: ...m diameter into the pipe The subsequent Stepps correspond to the installation of the ITABAR sensor type IBF 21 Oberserve the H dimension during the welding see also Fig 9 6 7 Installation of Type IBF...

Page 8: ...pressure transmitter should always be installed above the ITABAR sensor in order to avoid measurement degradation due to condensation and presence of solid particles see Fig 14 Fig 14 7 3 ITABAR senso...

Page 9: ...ng errors occur they may possibly be corrected quite easily error No differential pressure indication Correction Check whether all instrument valves to the p transmitter are opened Check the alignment...