Electrical installation
Kendrion INTORQ | BA 14.0223 | 04/2022
36
6.3.2
Technical specifications
Rectifier type
Bridge / half-wave rectifier
Output voltage for bridge rectification
0.9 x U
1
Output voltage for half-wave rectification
0.45 x U
1
Ambient temperature (storage/operation) [°C]
-25 – +70
U
1
input voltage (40 – 60 Hz)
Type
Input voltage U
1
(40 Hz – 60 Hz)
Max. current I
max
Over-excitation period t
ue
(± 20 %)
Min.
Rated
Max.
Bridge
half-wave
at U
1 min
at U
1 Nom
at U
1 max
[V~]
[V~]
[V~]
[A]
[A]
[s]
[s]
[s]
BEG-561-255-030
160
230
255
3.0
1.5
0.430
0.300
0.270
BEG-561-255-130
1.870
1.300
1.170
BEG-561-440-030-1
230
400
440
1.5
0.75
0.500
0.300
0.270
BEG-561-440-130
3.0
1.5
2.300
1.300
1.200
Tab. 8:
Data for bridge/half-wave rectifier type BEG-561
6.3.3
Reduced switch-off times
AC switching must also be carried out for the mains supply side switching (fast engagement)! Otherwise,
there will be no overexcitation when it is switched back on.
Delayed engagement
Fast engagement
Mains
Bridge
Coil
Mains
Coil