Electrical installation
INTORQ | BA 14.0199 | 08/2016
30
5.3
Technical data for inductive proximity sensors
5.3.1
Proximity sensor for release check
Design
PNP, N/O contact
Operating voltage
10 to 30 VDC
Permitted residual ripple
20% U
B
No-load current
Max. 10 mA
Output current
Max. 200 mA
Voltage drop at outputs
Max. 2.0 V at 200 mA
Short circuit protection
integrated
Reverse polarity protection
integrated
Induction protection
integrated
Protection class
IP67
Cable configuration and parameters
Cable (diameter / length / AWG)
Ø 3.3 mm / L = 2 m / AWG 26
Maximum cable length
100 m
Grey
Colour of sheath insulation
Brown (BN)
+ U
B
Black (BK)
Signal (with released armature plate - brake energized)
Blue (BU)
- U
B
Operating conditions
Ambient temperature range T
A
from -40 °C to +120 °C (no component damage)
from -25 °C to +120 °C (information analysis)
Shock and vibration
IEC 60947-5-2 / 7.4
EMC protection
IEC 60947-5-2 (7.2.3.1)
1 kV
IEC 61000-4-2
Level 2
IEC 61000-4-3
Level 3
IEC 61000-4-4
Level 2
Tab. 8:
Technical data for inductive proximity sensors (release check)