Technical specifications
INTORQ | BA 14.0199 | 08/2016
17
Switching times
Abb. 2
Operating/switching times of the spring-applied brakes
1) Typical values
2) Measured with induced voltage limitation of -800 V DC
t
1
Engagement time
t
11
Reaction delay of engagement
t
2
Disengagement time (up to M = 0.1 M
dyn
)
t
12
Rise time of the braking torque
M
dyn
Rated torque
U
Voltage
Type
Rated torque
Max. perm.
switching energy
Transitional
operating frequency
Operating times [ms]
1)
at s
LN
and 0.7 I
N
M
K
Q
E
S
hue
DC engagement
2)
Disengagement
[Nm]
[J]
[h
-1
]
t
11
t
12
t
1
t
2
BFK470-06
4
3000
79
16
25
41
32
BFK470-08
8
7500
50
30
26
56
52
BFK470-10
16
12000
40
40
64
104
107
BFK470-12
32
24000
30
47
34
81
121
BFK470-14
60
30000
28
30
47
76
162
BFK470-16
80
36000
27
46
62
109
255
BFK470-18
150
60000
20
62
92
155
343
Tab. 6:
Switching energy - operating frequency - operating times