Troubleshooting and fault elimination
INTORQ | BA 14.0168 | 09/2015
65
Rotor cannot rotate freely Wrong setting of manual
release
Check the dimension "s
LN
+ s
HL
" with the brake energised.
The dimension must be the same on both sides. Correct if
required (
41).
Air gap "s
L
" too small
Check air gap "s
L
" and adjust if necessary (
60).
Rotor thickness too small
Rotor has not been replaced
in time
Replace the rotor (
61).
Voltage too high
Brake voltage does not match
the rectifier
Adjust rectifier and brake voltage to each other.
Voltage too low
Brake voltage does not match
the rectifier
Adjust rectifier and brake voltage to each other.
Defective rectifier diode
Replace defective rectifier with a suitable undamaged one.
AC voltage is not mains
voltage
Fuse is missing or defective
Select a connection with proper fusing.
Fault
Cause
Remedy
Summary of Contents for BFK458-06***25