![INTORQ BFK458-06***25 Operating Instructions Manual Download Page 43](http://html1.mh-extra.com/html/intorq/bfk458-06-25/bfk458-06-25_operating-instructions-manual_2081628043.webp)
Electrical installation
INTORQ | BA 14.0168 | 09/2015
43
6.2
AC switching at the motor – extremely delayed engagement
Fig. 21
Supply: Phase-neutral
Bridge rectifier
Half-wave rectifier
BEG-1xx: U
N
[VDC]=0.9 •
[VAC]
BEG-2xx: U
N
[VDC]=0.45 •
[VAC]
Fig. 22
Supply: Phase-phase
Bridge rectifier
1)
Half-wave rectifier
BEG-1xx: U
N
[VDC]=0.9 • U
V
[VAC]
BEG-2xx: U
N
[VDC]=0.45 • U
V
[VAC]
1)
Not recommended for most regional/national high-voltage mains systems
U2
W2
V2
U
N
L1
L1 L2
L2 L3
L3
U
V
V1
U1
W1
U
V
BN
BK
BU
4
2
1
4-pole
BEG-14x
BEG-24x
6-pole
BEG-16x
BEG-26x
Uv
3
---------
Uv
3
---------
U2
W2
V2
U
N
L1
L1 L2
L2 L3
L3
U
V
V1
U1
W1
U
V
BN
BK
BU
4
2
1
4-pole
BEG-14x
BEG-24x
6-pole
BEG-16x
BEG-26x