Commissioning and operation
INTORQ | BA 14.0168 | 09/2015
55
7.3
Commissioning
1. Switch on your drive system.
2. Perform a test braking procedure; if necessary, reduce the braking torque (depending on your specifi-
cations and requirements)
7.4
Operation
❚
Checks must be carried out regularly. Pay special attention to:
-
unusual noises or temperatures
-
loose fixing elements
-
the condition of the electrical cables.
❚
Make sure that the armature plate is tightly attached and the drive moves without residual torque.
❚
Measure the DC voltage at the brake. Compare the measured DC voltage with the voltage indicated on
the nameplate. The deviation must be less than ± 10%!
DANGER
Danger: rotating parts!
❚
The running rotor must not be touched.
❚
Take structural design measures on your final product and implement organizational safety
rules to ensure that nobody can touch a rotor.
DANGER
There is a risk of injury by electrical shock!
❚
Live connections must not be touched.
❚
Take structural design measures on your final product and implement organizational safety
rules to ensure that nobody can touch a connection.