Technical specifications
INTORQ | BA 14.0215 | 07/2019
14
4
Technical specifications
4.1
Possible applications of the INTORQ spring-applied brake
¾
Degree of protection:
– The brake is designed for operation under the environmental conditions that apply to IP54 protec-
tion. Because of the numerous possibilities of using the brake, it is still necessary to check the func-
tionality of all mechanical components under the corresponding operating conditions.
¾
Ambient temperature:
– -20 °C to +40 °C (Standard)
¾
Humidity: no restrictions
– In the event of condensation or moisture formation: provide for appropriate ventilation of the brakes
to ensure that the friction pairs will dry quickly.
¾
Ambient temperature:
– -5 °C to +40 °C
¾
At high humidity and low temperature:
– Take the steps necessary to protect the armature plate and rotor from freezing.
¾
Protect the electrical connections against any contact or touching.
4.2
Rated data
sLN
sLN
Fig. 2:
Dimensions
Size
Rated torque
Air gap
Permissible
wear distance
Rotor thickness
Mass per
stator
s
LN
+0.22/-0.02
s
Lmax
Min.
Max.
m
[Nm]
[mm]
[mm]
[mm]
[mm]
[mm]
[kg]
25
2 x 800
0.3
0.6
0.3
12.7
13
35
2 x 1200
2 x 1500
Tab. 1:
Rated data for air gap specifications