133
SAVE THESE INSTRUCTIONS
Page 30
(133) MODEL CS8111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 11/17/2011
English
TROUBLESHOOTING GUIDE (continued)
TTRR
OOUU
BBLL
EESS
HHOO
OOTT
IINN
GG
GGUU
IIDD
EE
INSUFFICIENT
CHLORINE
INSUFFICIENT
COPPER ION
LEVEL
POOL IS STAINED
WHITE FLAKES IN
THE WATER
NO LED DISPLAY
GREEN HAIR
•
Insufficient operating hours of
the Saltwater System.
•
The salt level in the pool water
is less than 2000ppm. This is
insufficient.
•
Chlorine loss due to intense
sunlight exposure.
•
The bather load has increased.
•
Clogged or dirty electrolytic cell.
•
Insufficient operating hours.
•
The PH is too high.
•
The bather load has increased.
•
Clogged or dirty copper
electrode.
•
Copper electrode defective.
•
High copper ion concentration.
•
Excessive calcium hardness is
present in pool water.
•
No power supply.
• RCD/GFCI has not reseted.
•
A power fuse has blown.
•
LED failure.
• Incorrect switching, press two
buttons ( and ) together.
•
High copper ion concentration.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Check the salt level with the Test Kit. Adjust
as needed. See “Salt & Pool Water
Volumes”.
•
Use a pool cover when the pool is not in
use and/or when the unit is operating.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
•
Increase operating time per day. See
“Operating Instructions”.
•
Use PH decrease chemical to adjust,
contact your local pool chemical store.
•
Increase the operating time per day.
See “Operating Instructions”.
•
Remove the cell for inspection, clean it
if necessary. See “Maintenance”.
•
Contact Intex Service Center.
•
Drain about 20% of the pool water and
add fresh water to decrease the copper
ion concentration below 0.2ppm.
•
Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
• Use a lemon based cleaning product
(preferably containing citric acid). Don’t
scrub with aggressive cleaning
products because this might etch the
underlying surface.
•
Drain about 20 to 25% of the pool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
•
Plug the cell cord firmly into the cell housing
receptacle.
•
Reset the RCD/GFCI.
•
Contact Intex Service Center.
•
Contact Intex Service Center.
•
Shut down and turn on the power again,
re-set the time. See “Operating Instructions”.
•
Drain about 20% of the pool water and
add fresh water to decrease the copper
ion concentration below 0.2ppm.
•
Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
• Use ‘Ultra-Swim’ shampoo, or shampoo
containing chelating agents.
PROBLEM CAUSE SOLUTION
IMPORTANT
If you continue to experience difficulty, please contact our Consumer
Service Department for assistance. See back cover for contact information.