133
SAVE THESE INSTRUCTIONS
Page 19
(133) MODEL CS8111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 11/17/2011
English
SALT TABLE FOR COMMON NON-INTEX POOLS
OPERATING TIME TABLE FOR COMMON NON-INTEX POOLS
SALT CALCULATION FORMULA FOR ALL POOLS
Water Capacity
Salt Needed for Startup
Salt Needed when
Low Salt Detected
(CODE “91”)
(Gals)
(Liters)
(Lbs)
(Kgs)
(Lbs)
(Kgs)
2000
7500
50
20
10
5
4000
15000
100
45
25
10
6000
22500
150
65
40
20
8000
30000
200
90
55
25
10000
37500
250
110
70
30
12000
45500
300
135
80
35
14000
53000
350
160
95
45
Salt Needed for Startup
(Lbs)
Salt Needed for Startup
(Kgs)
Salt Needed when
Low Salt Detected (Lbs)
Salt Needed when
Low Salt Detected (Kgs)
Water Capacity (Gals) x 0.025 Water Capacity (Liters) x 0.003
Water Capacity (Gals) x 0.0067
Water Capacity (Liters) x 0.0008
CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS
Water Capacity
Operating Time (hours)
at different ambient/air temperatures
(Gals)
(Liters)
10 - 19°C
(50 - 66°F)
20 - 28°C
(68 - 82°F)
29 - 36°C
(84 - 97°F)
2000
4000
6000
8000
10000
12000
14000
7500
15000
22500
30000
37500
45500
53000
1
2
2
3
4
5
6
1
2
3
4
5
6
7
1
2
2
3
4
5
6
Water Capacity
Cyanuric Acid Needed for Startup
0.03g/L (30ppm)
(Gals)
(Liters)
(Lbs)
(Kgs)
2000
4000
6000
8000
10000
12000
14000
7500
15000
22500
30000
37500
45500
53000
0.23
0.45
0.68
0.90
1.13
1.37
1.59
0.5
1.0
1.5
2.0
2.5
3.0
3.5