background image

(249IO)  MODEL ECO7221/7231  Cartridge Filter Pump & Saltwater System with E.C.O.  ENGLISH  7.5” X 10.3”  PANTONE 295U  04/13/2017

249A

SAVE THESE INSTRUCTIONS

English

Page 18

SALTWATER SYSTEM OPERATION (continued)

5

Boost cycle:

• 

First time installation, press and hold “BOOST” button for 5 seconds until the 

 

indicator lights up and the LED display “80”. This indicates that the saltwater 

 

system has started more chlorine sanitizer production. You can press and    

 

hold the “BOOST” button for another 5 seconds until the indicator is off,  

 

 

which will cancel the Boost cycle. 

 

 

• 

The boost operating hours is 8 times the amount of time programmed into the 

 

system, i.e. if your saltwater system operating time is 2 hours, the boost procedure will run 

 

8 x 2 = 16 hours. After boost procedure has been completed, the system will automatically 

 

switch to the normal working mode.

• 

After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the pool again.

6.  Stand-by/power saving mode:

• 

When the cycle ends, the green “SLEEP” indicator on the 

 

control panel lights up and the LED display flashes “93”.  

 

 

 

 

The system is now in Stand-By mode. After a while, it  

 

shuts down and sets itself in a Power Saving mode. The 

 

system will automatically turn itself back on in 24 hours, 

 

starting its daily cycle of chlorine production.

• 

The “SLEEP” indicator stays on, while the system is in the    

 

 

 

Power Saving mode. The LED display however, goes blank 

 

after 5 minutes. Press any button (      or      ) to view the last 

 LED 

code.

7.  Running the pump alone without the Saltwater System:

 

To run the pump alone without the Saltwater System function,

 

press and hold both     and     buttons until you hear a “beep”,  

 

 

the LED display will show “FP”. The pump is now operating   

 

 

 

 

alone. NOTE: The pump cannot be operated alone under an 

 

automatic timer mode. To stop the pump, manually turn 

 

the switch OFF.

To bring back the initial automatic operating cycle setting 
of the Saltwater System:

 

a)   If the LED display shows “FP”, press the      button and 

 

 

the operating hours set previously will begin flashing, 

 

 

press the      button again or simply wait 1 minute, and 

 

 

the LED will stay illuminated. The Saltwater System 

 

 

cycle repeats again.

 

b)   If the unit is OFF, turn the switch ON, the LED display 

 

 

shows “FP”, press the     button and the operating hours 

 

 

set previously will begin flashing, press the      button 

 

 

again or simply wait 1 minute, and the LED will stay 

 

 

illuminated. The Saltwater System cycle repeats again.

Summary of Contents for ECO 7221

Page 1: ...lt in updates to the instruction manual without notice 2017 Intex Marketing Ltd Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los dere...

Page 2: ...Volumes 11 Intex Pools Salt Table 12 Intex Pools Cyanuric Acid Table 13 Intex Pools Operating Time Table 14 Non Intex Pools Salt Table 15 Non Intex Pools Cyanuric Acid Table 15 Non Intex Pools Operati...

Page 3: ...d it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard To reduce the risk of electric shock do not use extension cords timers plug adapto...

Page 4: ...glish Page 4 PARTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts Optional NOTE Drawings for illustration purpose only...

Page 5: ...LYTIC CELL HOUSING O RING C INCLUDED 1 11906 14 SECONDARY ELECTROLYTIC CELL 1 11900 15 L SHAPE O RING 1 11228 16 O RING C 1 10712 17 ANGLE JOINT O RING D INCLUDED 1 11584 18 O RING A 1 11587 19 PLUNGE...

Page 6: ...o make it slightly salty The pool water flows through the saltwater system s electrolytic cell 31 to produce HCLO The HCLO dissolves in the water and instantly starts destroying bacteria and algae It...

Page 7: ...m plates Strainer Plunger Valve Setup small AGP The strainer grid prevents large objects from jamming and or damaging the filter pump The plunger valve assembly prevents water from flowing into the fi...

Page 8: ...flat washer 23 on the connector 24 3 Install the strainer and plunger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 24 into one of the pre c...

Page 9: ...ricate the threads with a petroleum jelly Then with the flat side of the strainer nut 22 facing the outside wall of the liner in a clockwise motion screw the strainer nut 22 back onto the inlet thread...

Page 10: ...he Saltwater System Filter Pump is an airtight system In a counter clockwise motion turn both air release valves 1 7 1 2 turns to open DO NOT remove air release valves as water will expel with force i...

Page 11: ...cessories The Salt Table page of this manual shows the correct dosage of salt needed The salt in the pool is constantly recycled Salt loss occurs only when pool water is physically removed from the po...

Page 12: ...0 488cmx122cm 16 x48 4273 16173 110 50 30 15 488cmx132cm 16 x52 4614 17464 115 50 30 15 549cmx107cm 18 x42 4786 18115 120 55 30 15 549cmx122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL...

Page 13: ...l Pool Cyanuric Acid Needed for Startup 0 03g L 30 ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cmx84cm 15 x33 2587 9792 0 6 0 3 457cmx91cm 15 x36 2822 10681 0 7 0 3 457cmx1...

Page 14: ...3754 14209 4 5 6 488cmx122cm 16 x48 4273 16173 4 5 6 488cmx132cm 16 x52 4614 17464 5 6 7 549cmx107cm 18 x42 4786 18115 5 6 7 549cmx122cm 18 x48 5455 20647 6 7 8 CIRCULAR METAL FRAME POOL 457cmx91cm 1...

Page 15: ...ers x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 CYANURIC ACID TABLE FOR COMMON NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91...

Page 16: ...s occurs gently finger tighten the valves in a clockwise direction 5 Turn on the switch The filter pump is now filtering the water 6 The green Pump light on the control panel will light up that indica...

Page 17: ...rs maximum If you have selected too many hours keep pressing to repeat the cycle The built in timer will now activate your Saltwater System at the same time each day for the number of hours you have s...

Page 18: ...Stand By mode After a while it shuts down and sets itself in a Power Saving mode The system will automatically turn itself back on in 24 hours starting its daily cycle of chlorine production The SLEEP...

Page 19: ...s remaining 04 Operating Hours 4 hours remaining 05 Operating Hours 5 hours remaining 06 Operating Hours 6 hours remaining 07 Operating Hours 7 hours remaining 08 Operating Hours 8 hours remaining 09...

Page 20: ...assembly must exceed 18kg The European norm EN 60335 2 41 requires this product be secured to the ground or to a base 1 The mounting holes are 6 4 mm in diameter and spaced 242 5 mm apart 2 Use two b...

Page 21: ...locator notch on the flow sensor to the connection ridge in the conduit Now turn the collar in a clockwise motion tightening the sensor back into its position Do not overtighten The electrodes have a...

Page 22: ...he hose with nut 8 from the Saltwater System and assemble the cell cover 30 at the side of the cell 4 Unscrew the collar of the secondary electrolytic cell 14 and pull out the secondary electrolytic c...

Page 23: ...ntly unscrew and remove the sediment valve 1 located at the bottom of the housing Place it in a safe place B With a bucket of water or a garden hose pour water into the housing flushing out the sedime...

Page 24: ...ling the pool as well as during the season Consult your local swimming pool supply store for instructions The season s first filling of the pool may have brackish water requiring extra water additives...

Page 25: ...r eye skin irritation poor Chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result if too high Eye skin irritation difficulty balancing water a...

Page 26: ...Circuit Interrupter or RCD Reset circuit breaker If circuit breaker trips repeatedly your electrical system may have a defect Turn off circuit breaker and call an electrician to correct the problem Le...

Page 27: ...Saltwater System operating time See Operating Instructions Check the salt level with the Test Kit Adjust as needed See Salt Pool Water Volumes Use a pool cover when the pool is not in use and or when...

Page 28: ...he outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor recep...

Page 29: ...er all risks and dangers For additional safeguards also familiarize yourself with the following general guidelines as well as guidelines provided by nationally recognized Safety Organizations Demand c...

Page 30: ...the Service Center will inspect the item and determine the validity of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or compar...

Reviews: