(249IO) MODEL ECO7221/7231 Cartridge Filter Pump & Saltwater System with E.C.O. ENGLISH 7.5” X 10.3” PANTONE 295U 04/13/2017
249A
SAVE THESE INSTRUCTIONS
English
Page 16
FILTER PUMP OPERATION
1
. Make sure the unit is switched off. The switch is located on the control station.
2
. Connect the power cord to a RCD protected electrical outlet.
3
. Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valve,
allowing water to flow into the filter pump.
4
. With water flowing into unit, the water pressure will allow the air trapped inside to escape
from the air release valves
(1 & 7)
. When all the air has escaped water will flow out of the
valves
(1 & 7)
. When this occurs gently finger tighten the valves in a clockwise direction.
5
. Turn on the switch. The filter pump is now filtering the water.
6
. The green "Pump" light on the control panel will light up, that indicates the filter pump is
running.
To prevent air lock, open the lower plunger valve (connected inlet hose) first and then
the upper plunger valve (connected outlet hose). Open air release valves, lift and lower
the inlet hose until water starts to flow out of the air release valves, close air release
valves.
IMPORTANT
WARNING
Risk of electric shock. Connect this product only to a grounding type receptacle
protected by a residual current device (RCD). Contact a qualified electrician if you
cannot verify that the receptacle is protected by a RCD. Use a qualified electrician to
install the RCD, which has a maximum rate of 30 mA. Do not use a portable residual
current device (PRCD).
7
1