background image

 

 
 

 

  

 
 

1.  General 

 

AQUALOOP-TAP

 (AL-TAP) is a water filter for the disinfection of water. The cleaning principle is 

based  on  ultrafiltration  membrane  technology,  upon  which  substances  in  the  water,  like 
microorganisms such as bacteria and viruses, are withheld. 
 
The result of filtration is clear, hygenic water (Pay attention to safety instructions, Cap. 2). 
 
For more information on the filtration performance, see the link below: 
 

http://www.intewa.de/products/aqualoop/technik/membranen/ 

 

AL-TAP

 filters the water only due to the geodetic gravity and is therefore completely independent 

from electricity. 

 
 

The following raw water sources can be treated by 

AL-TAP

  Rainwater 

  Surface water 

  River water 

  Well water 

 

The following raw water sources cannot be treated by AL-TAP: 

  Raw  water  with  dissolved  organic  or  inorganic  substances  which  exceed  the  drinking 

water regulation limits 

  Domestic and industrial wastewater  

 

Application areas: 

  Households, schools, homes 

  Camping grounds / Field camps 

  Emergency aid 

  Disaster response 

 

Advantages: 

  No electric power necessary 

  Small footprint, only one tank 

  Easy installation, commissioning and operation 

  Removal (membrane barrier) of solids, bacteria, viruses, worm eggs  

  No chemicals necessary during operation 

  Robust process, no precision mechanical parts 

  If necessary, easy cleaning (mechanical and chemical) 

 
 
 

Summary of Contents for AQUALOOP tap

Page 1: ...AQUALOOP TAP Portable drinking water production up to 1600 L day Disinfection of water with power free geodetic pressure www intewa de Assembly and Operating Instructions ...

Page 2: ...Deliverables 3 4 Technical Data 4 5 Installation 5 6 System Venting and Filtration Operation 7 7 Cleaning and Storage 9 7 1 Mechanical Cleaning 9 7 2 Chemical Cleaning 10 7 3 Storage 10 8 Replacement Parts and Cleaning Supplies 11 9 Warranty 11 10 Contact 11 ...

Page 3: ... independent from electricity The following raw water sources can be treated by AL TAP Rainwater Surface water River water Well water The following raw water sources cannot be treated by AL TAP Raw water with dissolved organic or inorganic substances which exceed the drinking water regulation limits Domestic and industrial wastewater Application areas Households schools homes Camping grounds Field...

Page 4: ... the treated water side must also be avoided ie as a result of contamination of the outlet valve This must never lie on the ground but must hang freely If the system is not used regularly the hose system must be cleaned before use The following points must be adhered to for the installation and operation Inspect the product before installation for any visible defects If defects are present the pro...

Page 5: ...range 0 55 C Max membrane pressure 0 7 bar Max free chlorine 25 C or less 5000 ppm 5 pH during chemical cleaning Max cleaning load free chlorine 1 Mil ppmh cumulative hourly Material HD PE food safe Tank Total weight incl packing 8 kg Membrane cartridge service life up to 10 years 1 Tank 2 Membrane cartridge 3 Ventilation 4 Ventilation valve V1 5 Stop valve V2 6 Suction hose 7 Outlet valve V3 ...

Page 6: ...s This side is provided with the elbow connection a Top side b Filtration connection under Installation 1 Mount the membrane cartridge with connecting bend in the tank locknut Note The rubber seal must lie on the inside of the container wall 2 Remove the yellow protective plug on the connection and screw into the storage hole in the tank lid The protective plug is required for the mechanical clean...

Page 7: ...6 3 Assemble the valve unit and ventilation hose 4 Place the AL TAP in an elevated position and assemble hose If necessary shorten suction hose Δ H ...

Page 8: ... 2 Fill the container with water so that the cartridge is submerged with at least 10 cm of water above 10 cm 3 Wait until the suction hose after stretching out it should hang down is completely filled with water and the water level in the ventilation hose has equalized with the water level in the container approx 10 20 minutes V1 OFFEN V2 OFFEN V3 ZU V1 V2 V3 ...

Page 9: ...00 L day 0 2 L min 288 L day 1 m 2 0 L min 2880 L day 0 6 L min 864 L day 2 m 3 2 L min 4608 L day 1 0 L min 1440 L day 3 m 4 4 L min 6336 L day 1 4 L min 2016 L day Note The flow rate is strongly dependent on the raw water quality and membrane blockage The suction pressure is only ready if the suction hose is completely vented Table Flow rate as a function of the suction height H and blockage Dur...

Page 10: ... valve unit and close the connection with the yellow protective plug 2 Loosen the lock nut and remove the membrane cartridge with elbow connection out of the container 3 After close the container with sealing plugs 4 Fill tank to full with water and flush the membrane with plunging movements approx 20 times In reverse order remount the membrane unit and ventilate as described in Chap 6 ...

Page 11: ...rane cartridge with water equivalent to approx 36 L 2 Start filtration for 6 Liter 3 After 2 hrs filter the water through the membrane to empty 4 If the filtration performance is not achieved see flow rate table repeat above steps 1 3 5 Rinse the system with at least 30 litres of water Cleaning steps for chlorine cleaning 1 Fill the container half full of water and add a single dose of cleaning so...

Page 12: ...ich affect the value or usability of the device only insignificantly Caution For the quality of the filtered water the user is responsible The use of the filtered water for drinking water purposes may only occur with a valid water analysis Regular analyses are necessary for quality assurance 10 Contact For customers in Germany For questions ordering spare parts and for service cases please contact...

Page 13: ...12 INTEWA GmbH Version 1 0 b Subject to technical changes ...