background image

 

 
 

 

  

 
 

2.  Safety Precautions 

 

 

Before  installing  the  product,  these  installation  and  operating  instructions 
must  be  read  carefully.  The  indicated  instructions  herein  must  be  strictly 
observed.  Modifications  to  the  product  are  not  permitted,  otherwise  any 
warranty expires.

 

 

Chemicals  in  the  raw  water  are  not  removed  by  the  filter!  Therefore, 
depending  on  the  water  source,  a  preliminary  raw  water  analysis  should  be 
carried out. 

Periodically, the hose system must be cleaned or replaced in order to avoid 
contamination of the treated water.

 

 

For  drinking  water  applications,  the  treated  water  must  be  analyzed 
prior to use

. Contamination on the treated water side must also be avoided 

ie. as a result of contamination of the outlet valve. This must never lie on the 
ground but must hang freely.  

If the system is not used regularly, the hose system must be cleaned before 
use.

 

 

The following points must be adhered to for the installation and operation: 

 

Inspect  the  product  before  installation  for  any  visible  defects.  If  defects  are  present,  the 
product may not be installed. 

 

All products must be checked regularly for proper condition. 

 

If  deterioration  of  the  filtration  results  occurs  (eg.  turbidity  increases),  the  system  must  be 
immediately stopped, cleaned and checked. 

 

The operator is responsible for compliance with safety and installation requirements. 

 
 
 

3.  Deliverables 

 
 

 

 
 

              

 

 
 
 
 

 

60 litre container

 

Membrane cartridge and 
tank fasteners

 

Valve unit with ventilation and 
suction hose

 

Summary of Contents for AQUALOOP tap

Page 1: ...AQUALOOP TAP Portable drinking water production up to 1600 L day Disinfection of water with power free geodetic pressure www intewa de Assembly and Operating Instructions ...

Page 2: ...Deliverables 3 4 Technical Data 4 5 Installation 5 6 System Venting and Filtration Operation 7 7 Cleaning and Storage 9 7 1 Mechanical Cleaning 9 7 2 Chemical Cleaning 10 7 3 Storage 10 8 Replacement Parts and Cleaning Supplies 11 9 Warranty 11 10 Contact 11 ...

Page 3: ... independent from electricity The following raw water sources can be treated by AL TAP Rainwater Surface water River water Well water The following raw water sources cannot be treated by AL TAP Raw water with dissolved organic or inorganic substances which exceed the drinking water regulation limits Domestic and industrial wastewater Application areas Households schools homes Camping grounds Field...

Page 4: ... the treated water side must also be avoided ie as a result of contamination of the outlet valve This must never lie on the ground but must hang freely If the system is not used regularly the hose system must be cleaned before use The following points must be adhered to for the installation and operation Inspect the product before installation for any visible defects If defects are present the pro...

Page 5: ...range 0 55 C Max membrane pressure 0 7 bar Max free chlorine 25 C or less 5000 ppm 5 pH during chemical cleaning Max cleaning load free chlorine 1 Mil ppmh cumulative hourly Material HD PE food safe Tank Total weight incl packing 8 kg Membrane cartridge service life up to 10 years 1 Tank 2 Membrane cartridge 3 Ventilation 4 Ventilation valve V1 5 Stop valve V2 6 Suction hose 7 Outlet valve V3 ...

Page 6: ...s This side is provided with the elbow connection a Top side b Filtration connection under Installation 1 Mount the membrane cartridge with connecting bend in the tank locknut Note The rubber seal must lie on the inside of the container wall 2 Remove the yellow protective plug on the connection and screw into the storage hole in the tank lid The protective plug is required for the mechanical clean...

Page 7: ...6 3 Assemble the valve unit and ventilation hose 4 Place the AL TAP in an elevated position and assemble hose If necessary shorten suction hose Δ H ...

Page 8: ... 2 Fill the container with water so that the cartridge is submerged with at least 10 cm of water above 10 cm 3 Wait until the suction hose after stretching out it should hang down is completely filled with water and the water level in the ventilation hose has equalized with the water level in the container approx 10 20 minutes V1 OFFEN V2 OFFEN V3 ZU V1 V2 V3 ...

Page 9: ...00 L day 0 2 L min 288 L day 1 m 2 0 L min 2880 L day 0 6 L min 864 L day 2 m 3 2 L min 4608 L day 1 0 L min 1440 L day 3 m 4 4 L min 6336 L day 1 4 L min 2016 L day Note The flow rate is strongly dependent on the raw water quality and membrane blockage The suction pressure is only ready if the suction hose is completely vented Table Flow rate as a function of the suction height H and blockage Dur...

Page 10: ... valve unit and close the connection with the yellow protective plug 2 Loosen the lock nut and remove the membrane cartridge with elbow connection out of the container 3 After close the container with sealing plugs 4 Fill tank to full with water and flush the membrane with plunging movements approx 20 times In reverse order remount the membrane unit and ventilate as described in Chap 6 ...

Page 11: ...rane cartridge with water equivalent to approx 36 L 2 Start filtration for 6 Liter 3 After 2 hrs filter the water through the membrane to empty 4 If the filtration performance is not achieved see flow rate table repeat above steps 1 3 5 Rinse the system with at least 30 litres of water Cleaning steps for chlorine cleaning 1 Fill the container half full of water and add a single dose of cleaning so...

Page 12: ...ich affect the value or usability of the device only insignificantly Caution For the quality of the filtered water the user is responsible The use of the filtered water for drinking water purposes may only occur with a valid water analysis Regular analyses are necessary for quality assurance 10 Contact For customers in Germany For questions ordering spare parts and for service cases please contact...

Page 13: ...12 INTEWA GmbH Version 1 0 b Subject to technical changes ...