Remote Switching Input 

The SPCi has a special isolation feature which allows the unit to be remotely turned on/off by using 

a simple (N/O) switch to isolate the output.  The switch can be in the form of any normally open (N/O) 

latching device i.e. toggle, ignition, push-button, etc.  
The remote isolation circuit is activated by using the R terminal as the input signal.  This circuit is 

switched via any 8-32VDC source that is independent of the output side of the SPCi.  For example the 

feed can be connected directly to the +24VDC input terminal of the SPCi or from a remote source more 

conveniently located to the control switch if desired. This control feature can be utilised in different ways 

including the following: 
•  For safety or convenience purposes it is quite often necessary, for example, to isolate all equipment 

when the ignition is turned off in a vehicle.  In this instance any equipment connected to the 24VDC 

output of the SPCi is immediately disconnected when the ignition switch is turned off and the key 

removed.

•  The SPCi can be used as a fully automatic switching device where there is a requirement to switch 

24VDC equipment via a 24VDC source.  For example, a fl oat switch or daylight switch can be connected 

via the remote input terminal and used to switch the output of the SPCi on or off automatically.  

The Remote input requires a trigger voltage of 8-32VDC to activate the internal control circuit. This is 

signal current (<5mA) only so the terminal can be wired with extra low power control or data cable. 
NOTE: In the event the Remote (R) terminal is connected, the SPCi will memorise the connection, even 

if the input supply is disconnected. This is a requirement in order for the function to operate correctly. 

Should it be necessary to discontinue the use of this function, a full system reset will need to be 

performed. Isolate the 24V input to the SPCi. Remove the wire connected to the Remote (R) terminal. 
Re-apply the 24V supply – the POWER Icon  

  does not illuminate. Press and hold the SET button  

  

until the POWER icon      illuminates (this will take approximately 1 minute). The SPCi is now operational 

and in standby mode again.

12

SCHE
M

AT

IC

S

POWER CONDITIONER

Parallel Installation 

Output voltage setting MUST be the same for each unit connected in parallel.

INPUT

AUX.

+24V –0V

R

A

+24V

-0V

OUTPUT

INPUT

AUX.

+24V –0V

R

A

+24V

-0V

OUTPUT

+

+

12V

12V

FUSE

FUSE

24V nominal

24V DC EQUIPMENT

11

SCHE
M

AT

IC

S

POWER CONDITIONER

Standard Installation

INPUT

AUX.

+24V –0V

R

A

+24V

-0V

OUTPUT

+

+

12V

24V DC EQUIPMENT

12V

FUSE

24V nominal

SCHEMATICS

13

SCHE
M

AT

IC

S

BATTERY CHARGER

Standard Installation

INPUT

AUX.

+24V –0V

R

A

+24V

-0V

OUTPUT

+

+

12V

12V

FUSE

24V nominal

+

+

12V

12V

Summary of Contents for Gen II Maxi Series

Page 1: ...midity environments They are constructed of quality marine grade materials and when applied and installed correctly are designed to provide many years of continuous service Intervolt SPCi s are design...

Page 2: ...conductivity Itisrecommended thatpropertinneddrawn coppercablelugsareusedfortermination Anexampleofthisitemis depictedonpage6 3 NOTICE TheSPCimustbeproperlyinstalledinordertocomplywithenvironmentalope...

Page 3: ...time PressandholdtheSETbutton for30secondsuntilalliconsontheoperatorinterfacedisplayareilluminated pulsing ReleasetheSETbutton andthefactorydefaultsettingswillberestoredatwhichpointthe illuminatedicon...

Page 4: ...oteinputterminalandusedtoswitchtheoutputoftheSPCionoroffautomatically TheRemoteinputrequiresatriggervoltageof8 32VDCtoactivatetheinternalcontrolcircuit Thisis signalcurrent 5mA onlysotheterminalcanbew...

Page 5: ...e lowinput voltageandlowoutputvoltage batterychargingmodeonly priortoshutdown Thesealarmfunctions canbeoutputforremotemonitoring Shutdownprotectionforcriticalfaultconditionssuchasoverload overtemperat...

Page 6: ...willcontinuetooperatein thisconditionprovidingthevoltagedoesnotfall toshutdownmode Thealarmconditionisself resettingshouldthefaultconditionreverttonormal 19 OPERATOR INTERFACE INPUT ICON TheINPUTindic...

Page 7: ...g oftheSPCi Continuousloadshouldnotexceed100 ofthe maximumratingoftheSPCispeci cation Innormalmode onlythegreenbarswillbeilluminatedcontinuously steady Iftheunitisoverloadedtheamberbarwillbeilluminate...

Page 8: ...AustralianCTickmarkandEuropeanCEmark LengthOverall 170mm 230mm WidthOverall 110mm 110mm HeightOverall 55mm 55mm Weight 830grams 1150grams Basedona50 dutycycleat5minuteintervalsoverandabovethecontinuou...

Reviews: