In the event the battery charging (24V) mode is 

selected (see set-up instructions)  the CHARGE icon 

is permanently illuminated in addition to the normal 

POWER indicator icon.  The charging mode is indicated in 

two possible states:
–   The CHARGE icon is illuminated intermittently 

(pulsing amber). In this state the battery charging 

output is in boost mode (stage 1) and operating 

normally.

–  The CHARGE icon is illuminated continuously (steady 

amber).  In this state the battery charging output is in 

fl oat mode (stage 2) and operating normally.

24

TR

O

U

B

LE

SH

O

O

TI

N

G

INDICATION

ICON STATUS

CAUSE

REMEDY

POWER icon 

Illuminated 

(pulsing green). 

The SPCi  is 

operating 

normally.

N/A.

N/A.

POWER icon 

not illuminated.

The SPCi  is not 

in service.

No 24VDC supply available 

at input terminals.
Remote isolation control 

may be enabled.
Unit has failed due to internal fault.

Check input voltage supply i.e. 

connection and/or fuse.
Turn on remote isolation switch or 

perform system reset (see page 11). 
Return to vendor for servicing.

TEMP icon 

illuminated 

(pulsing red).

The SPCi  is 

overheating. 

Excessive environmental 

temperature.
Ventilated end cap is 

blocked or obstructed.
Cooling fan is not operating 

(FAN icon illuminated).

Re-locate SPCi  to cooler location.

Remove blockage or obstruction to 

enable heat to ventilate (exhaust).
See FAN icon fault fi nding 

indication (above).

TEMP icon 

illuminated 

(steady red). 

The SPCi  has 

shutdown due 

to overheating.

Excessive environmental 

temperature
Ventilated end cap is 

blocked or obstructed
Cooling fan is not operating 

(FAN icon illuminated)
SPCi  has been continually 

overloaded to temperature 

shutdown point

Re-locate SPCi  to cooler location

Remove blockage or obstruction to 

enable heat to ventilate (exhaust)
See FAN icon fault fi nding 

indication (above).
Rectify overload/short 

circuit condition.

23

O

PER
AT

O

R

 IN

TER

FA

CE

OUTPUT LOAD INDICATOR

The OUTPUT LOAD indicator is used to display the value of 

the load connected to the 24V output.  The indicator consists 

of fi ve LED bars from 25 to 125% (four green and one amber).  

Push SET button momentarily to display the load in percentage 

terms on the output.  The percentage is based on the rating 

of the SPCi. Continuous load should not exceed 100% of the 

maximum rating of the SPCi specifi cation.  In normal mode 

only the green bars will be illuminated continuously (steady).  

If the unit is overloaded the amber bar will be illuminated 

continuously (steady) indicating 125% of load in addition to the 

OUTPUT warning indicator. The display will indicate for 60 

seconds before turning off automatically.

OUTPUT VOLTS INDICATOR

The OUTPUT VOLTS indicator is used to display the user 

selected voltage of the SPCi (see set-up instructions).  The 

indicator consists of 5 LED bars from 24.0V to 28.0V in 1.0V 

increments.  The fi rst four bars are illuminated green and 

the fi fth amber. The factory default setting is 26.0V which will 

indicate for 10 seconds when powered up from the 24VDC 

supply.  If the output voltage setting has been changed the 

new setting will be displayed each time the unit is powered 

up. The display will indicate for 10 seconds before turning off 

automatically.

25

TR

O

U

B

LE

SH

O

O

TI

N

G

INDICATION

ICON STATUS

CAUSE

REMEDY

FAN icon  

Illuminated 

(steady red). 

The SPCi  cooling 

fan has ceased 

operating. 

Cooling fan has failed.
Cooling fan is obstructed.

Return to vendor for servicing.
Check ventilated end cap for any 

visible obstruction and remove/rectify.

INPUT icon 

illuminated 

(pulsing red).

The SPCi  is 

sensing low 

input voltage.

Input voltage is falling or dipping 

towards the factory preset limit.

Check input supply voltage.

INPUT icon 

illuminated 

(steady red).

The SPCi  has 

shutdown due to 

low input voltage.

Input voltage has fallen below 

the factory preset limit.

Check input supply voltage.

OUTPUT icon 

illuminated 

(pulsing red). 

The SPCi  

is being 

overloaded.

Output current is exceeding 

the continuous load rating.
Output voltage (charge mode 

only) is falling or dipping towards 

the factory preset limit.

Reduce load on output.

Check condition and/or state of 

24V battery connected to output.

OUTPUT icon 

illuminated 

(steady red).

The SPCi  has 

shutdown due 

to overload or 

short circuit.

Output current has exceeded 

the maximum load rating.
Output supply is short circuited.

Output voltage (charge mode only) 

has fallen below factory preset limit.

Reduce load on output.

Check for short circuits on 

output and rectify.
Check condition and/or state of 

24V battery connected to output.

OVERLOAD 

icon illuminated 

(pulsing amber).

The SPCi  

is being 

overloaded.

Output current is exceeding 

the continuous load rating.

Reduce load on output.

Summary of Contents for Gen II Maxi Series

Page 1: ...midity environments They are constructed of quality marine grade materials and when applied and installed correctly are designed to provide many years of continuous service Intervolt SPCi s are design...

Page 2: ...conductivity Itisrecommended thatpropertinneddrawn coppercablelugsareusedfortermination Anexampleofthisitemis depictedonpage6 3 NOTICE TheSPCimustbeproperlyinstalledinordertocomplywithenvironmentalope...

Page 3: ...time PressandholdtheSETbutton for30secondsuntilalliconsontheoperatorinterfacedisplayareilluminated pulsing ReleasetheSETbutton andthefactorydefaultsettingswillberestoredatwhichpointthe illuminatedicon...

Page 4: ...oteinputterminalandusedtoswitchtheoutputoftheSPCionoroffautomatically TheRemoteinputrequiresatriggervoltageof8 32VDCtoactivatetheinternalcontrolcircuit Thisis signalcurrent 5mA onlysotheterminalcanbew...

Page 5: ...e lowinput voltageandlowoutputvoltage batterychargingmodeonly priortoshutdown Thesealarmfunctions canbeoutputforremotemonitoring Shutdownprotectionforcriticalfaultconditionssuchasoverload overtemperat...

Page 6: ...willcontinuetooperatein thisconditionprovidingthevoltagedoesnotfall toshutdownmode Thealarmconditionisself resettingshouldthefaultconditionreverttonormal 19 OPERATOR INTERFACE INPUT ICON TheINPUTindic...

Page 7: ...g oftheSPCi Continuousloadshouldnotexceed100 ofthe maximumratingoftheSPCispeci cation Innormalmode onlythegreenbarswillbeilluminatedcontinuously steady Iftheunitisoverloadedtheamberbarwillbeilluminate...

Page 8: ...AustralianCTickmarkandEuropeanCEmark LengthOverall 170mm 230mm WidthOverall 110mm 110mm HeightOverall 55mm 55mm Weight 830grams 1150grams Basedona50 dutycycleat5minuteintervalsoverandabovethecontinuou...

Reviews: