22
O
PER
AT
O
R
IN
TER
FA
CE
CHARGE ICON
In the event the battery charging (24V) mode is
selected (see set-up instructions) the CHARGE icon
is permanently illuminated in addition to the normal
POWER indicator icon. The charging mode is indicated in
two possible states:
– The CHARGE icon is illuminated intermittently
(pulsing amber). In this state the battery charging
output is in boost mode (stage 1) and operating
normally.
– The CHARGE icon is illuminated continuously (steady
amber). In this state the battery charging output is in
fl oat mode (stage 2) and operating normally.
24
TR
O
U
B
LE
SH
O
O
TI
N
G
INDICATION
ICON STATUS
CAUSE
REMEDY
POWER icon
Illuminated
(pulsing green).
The SPCi is
operating
normally.
N/A.
N/A.
POWER icon
not illuminated.
The SPCi is not
in service.
No 24VDC supply available
at input terminals.
Remote isolation control
may be enabled.
Unit has failed due to internal fault.
Check input voltage supply i.e.
connection and/or fuse.
Turn on remote isolation switch or
perform system reset (see page 11).
Return to vendor for servicing.
TEMP icon
illuminated
(pulsing red).
The SPCi is
overheating.
Excessive environmental
temperature.
Ventilated end cap is
blocked or obstructed.
Cooling fan is not operating
(FAN icon illuminated).
Re-locate SPCi to cooler location.
Remove blockage or obstruction to
enable heat to ventilate (exhaust).
See FAN icon fault fi nding
indication (above).
TEMP icon
illuminated
(steady red).
The SPCi has
shutdown due
to overheating.
Excessive environmental
temperature
Ventilated end cap is
blocked or obstructed
Cooling fan is not operating
(FAN icon illuminated)
SPCi has been continually
overloaded to temperature
shutdown point
Re-locate SPCi to cooler location
Remove blockage or obstruction to
enable heat to ventilate (exhaust)
See FAN icon fault fi nding
indication (above).
Rectify overload/short
circuit condition.
23
O
PER
AT
O
R
IN
TER
FA
CE
OUTPUT LOAD INDICATOR
The OUTPUT LOAD indicator is used to display the value of
the load connected to the 24V output. The indicator consists
of fi ve LED bars from 25 to 125% (four green and one amber).
Push SET button momentarily to display the load in percentage
terms on the output. The percentage is based on the rating
of the SPCi. Continuous load should not exceed 100% of the
maximum rating of the SPCi specifi cation. In normal mode
only the green bars will be illuminated continuously (steady).
If the unit is overloaded the amber bar will be illuminated
continuously (steady) indicating 125% of load in addition to the
OUTPUT warning indicator. The display will indicate for 60
seconds before turning off automatically.
OUTPUT VOLTS INDICATOR
The OUTPUT VOLTS indicator is used to display the user
selected voltage of the SPCi (see set-up instructions). The
indicator consists of 5 LED bars from 24.0V to 28.0V in 1.0V
increments. The fi rst four bars are illuminated green and
the fi fth amber. The factory default setting is 26.0V which will
indicate for 10 seconds when powered up from the 24VDC
supply. If the output voltage setting has been changed the
new setting will be displayed each time the unit is powered
up. The display will indicate for 10 seconds before turning off
automatically.
25
TR
O
U
B
LE
SH
O
O
TI
N
G
INDICATION
ICON STATUS
CAUSE
REMEDY
FAN icon
Illuminated
(steady red).
The SPCi cooling
fan has ceased
operating.
Cooling fan has failed.
Cooling fan is obstructed.
Return to vendor for servicing.
Check ventilated end cap for any
visible obstruction and remove/rectify.
INPUT icon
illuminated
(pulsing red).
The SPCi is
sensing low
input voltage.
Input voltage is falling or dipping
towards the factory preset limit.
Check input supply voltage.
INPUT icon
illuminated
(steady red).
The SPCi has
shutdown due to
low input voltage.
Input voltage has fallen below
the factory preset limit.
Check input supply voltage.
OUTPUT icon
illuminated
(pulsing red).
The SPCi
is being
overloaded.
Output current is exceeding
the continuous load rating.
Output voltage (charge mode
only) is falling or dipping towards
the factory preset limit.
Reduce load on output.
Check condition and/or state of
24V battery connected to output.
OUTPUT icon
illuminated
(steady red).
The SPCi has
shutdown due
to overload or
short circuit.
Output current has exceeded
the maximum load rating.
Output supply is short circuited.
Output voltage (charge mode only)
has fallen below factory preset limit.
Reduce load on output.
Check for short circuits on
output and rectify.
Check condition and/or state of
24V battery connected to output.
OVERLOAD
icon illuminated
(pulsing amber).
The SPCi
is being
overloaded.
Output current is exceeding
the continuous load rating.
Reduce load on output.