InterTest, Inc. • 908-496-8008
MZ-5™ FS Inspection System
EM15201 Rev A
Page
37
Version 1.0 • Nov 2020
iii. Setup parameters
iv. Video, video image still or 4K image still capture
6. System Features mechanical.
a. Control unit based on rack mount PC and power conditioning/backup unit installed in fan
cooled NEMA type enclosure on center conductor rack
b. Pole & cable handling system (central conductor rack optional)
i. Pole and center conductor handling system
ii. Festoon apparatus to manage cable.
c. Rugged cable (anaconda sheath) overall length from head to control unit nominal 80’
overall length measured from inspection head through pole to Central Conductor Rack
mounted on the Rack Table
7. System electrical
a. Earth ground required to NEMA enclosure
b. 120V/60Hz 30A earth ground power required (alternate power input optional)
c. Tripp-Lite 750 VA (600W) UPS power back up & power conditioning module.
Chapter 5 —
Care and
Maintenance
1)
Camera windows should only be cleaned with denatured alcohol & lens wipes