Spirotest 100 Model 2016
16
4.7 Automatic activation of positive pressure for Spiromatic
breathing valve
1. Manually put the positive pressure lever on the breathing valve to the OFF position.
2. Create a negative pressure in the breathing valve by pressing the Vacuum pump
button (10) and the Negative pressure button (14) at the same time.
3. As soon as the positive pressure lever (on breathing valve) changes position, record
the trigger pressure value on the Low pressure gauge (2) and note in the test
protocol.
4. Close the positive pressure lever (on breathing valve).
5. Disconnect the breathing valve from Test adapter BV P/Divator (I), and disconnect
the Test adapter BV P/Divator (I) from the Test connection (3).
4.8 Air supply capacity for Spiromatic breathing valve
1. Connect Test adapter MPE-P2 (K) to the Test connection (3).
2. Connect the black tube of the Test adapter MPE-P2 (K) to the inhalation channel of
the breathing valve.
NOTE: The inhalation channel of different breathing valves may differ in size. To
adjust for this, use the short black adapter ring on the connection tube of the Test
adapter MPE-P2 (K).
3. Hold the Test adapter MPE-P2 (K) in your hand and carefully manually activate (ON)
the positive pressure lever on the breathing valve. If the value on the Low pressure
gauge (2) rises above 10 mbar then close the positive pressure lever.
4. Record the value shown on the Low pressure gauge (2) in the test protocol.
5. Disconnect Test adapter MPE-P2 (K) from the breathing valve.
If a complete SCBA set is to be tested – go to section “6. Leak test of complete
apparatus with mask”.