ment. Relay-type Outstations are rated up to 1A, 48V and are NOT DE-
SIGNED FOR MAINS SWITCHING. 

The Main Units can be controlled by computer via the RS232 interface 
also. 

 

Operating Instructions

 

 

Unpacking and Connections. 

Unpack the Main Unit and place on a flat 

surface within easy reach of the operator. Set up the preferred mounting of 

the Main Unit by removing the bracket securing screws on each side of the 

Main Unit and repositioning each bracket for either 19” 2RU rack mounting 
or freestanding, and then replace and tighten the bracket securing screws. 

Mount the Main Unit in the rack unit if this is the preferred mounting con-

figuration. 

 
If multiple Main Units are being used and linked, mount these also and 

connect to each other using the RS232 (serial) connectors (loop output 

from Main Unit one to input of Main Unit two etc). 

 
Unpack the Outstations and install where required. Connect these to the 

Main Unit using high quality, standard 3 pin XLR (mic) cables (refer fig 1 

for connection options). 

 
Apply power to the Main Unit/s using the 12V DC power adaptor/s  pro-

vided and switch on the mains power. All LEDs in the system illuminate 

briefly to confirm that all are operational. The system is now ready for pro-

gramming or operation. 
 

Programming Outstations

  

 

1. 

With the system fully powered up, unplug the XLR input cable 

which is providing power to the Outstation and wait 10 seconds for 

the Outstation to fully power down (i.e. until all LED lamps on the 
Outstation are fully extinguished). 

2. 

While holding down the ‘Confirm’ button, reconnect power to the 

Outstation. Release the ‘Confirm’ button and the ‘Standby’ light will 
flash to confirm the Outstation is now in programme mode 

Summary of Contents for TheatreCue

Page 1: ...TheatreCue User Manual Cueing and Presentation Control Specialists...

Page 2: ...3 Safety Instructions 4 Setting Up 5 Operating Instructions 7 Programming Outstations 7 Main Unit Setup 9 Giving Cues 10 Testing and Faults 12 Certificate of Conformity 14 Environmental 15 Technical...

Page 3: ...le to quickly set up and assign remote stations in any preferred order and to either of two groups for the easy simultaneous cueing of multiple actions Stage managers are then able to give standby com...

Page 4: ...ply lead is damaged Using the device with a damaged power supply lead may expose you to electric shock or other hazards Check the condition of the power supply lead regularly Contact your dealer or se...

Page 5: ...or how to maintain the unit please do not hesitate to contact us on 44 0 870 770 8088 Servicing Do not attempt to service this product yourself Opening or removing covers and screws may expose you to...

Page 6: ...chain or loop configuration The loop configura tion allows the whole system to keep working even when a break in the cable exists Up to 8 Main Units can be linked also providing for control of up to 1...

Page 7: ...sing the RS232 serial connectors loop output from Main Unit one to input of Main Unit two etc Unpack the Outstations and install where required Connect these to the Main Unit using high quality standa...

Page 8: ...Main Unit will be updated immediately 5 If when the Outstation confirms the programming the number is incorrect and you need to change the number it is programmed to simply press the Confirm button t...

Page 9: ...igned to that Outstation will flash on the Main Unit When the Main Unit is in setup mode the status of this function is displayed by the channel 2 Go button The factory default LED on enabled Use the...

Page 10: ...e is given the Outstation Standby LED and Main Unit buttons will be extinguished and both the green Go LED on the Outstation and the Go button on the Main Unit will remain lit continuously for 5 6 sec...

Page 11: ...linked for larger systems providing for up to 112 Outstations See Main Unit Setup for more information on link ing Main Units Using the Beeper The Main Unit operator can give audible cues to beeper t...

Page 12: ...ons are normal the fault LED will remain OFF If there has never been an Outstation connected to that channel since initial power up the fault LED will remain ON continuously If no signal can be receiv...

Page 13: ...Go buttons all together again or power down the Main Unit Individual Outstation Lamp Test To lamp test any Outstation disconnect the power input XLR cable from the Outstation wait 10 seconds for the O...

Page 14: ...ts TheatreCue Part Nos CUERACK14 CUEOUT CUERELAY CUEBEEP CUE232 Conform to the following standards EN60950 1 2002 BS EN 55103 1 1997 BS EN 55103 2 1997 Following the provision of The Low Voltage Direc...

Page 15: ...ials Cardboard box Grade 150 K T B Single Walled Corrugated Brown Kraft Protective Foam Grade HLB 22 Grey Foam High Load Bearing Equipment Supplied 1 x TheatreCue Main Unit Outstations to order 12v DC...

Page 16: ...16 28 High Street Arlesey Bedfordshire SG15 6RA UK Tel 44 0 870 770 8088 Fax 44 0 870 770 8089 Email moreinfo interspaceind com www interspaceind com...

Reviews: