Version 2.4 (03/2020) Online
Translation of the original operating manual
19 of 54
Product information
Health indicator lights
So-called health or status indicator lights are used to monitor the current values of the RollerDrive.
Health indicator lights are used to check the
• Temperature
• Power
• Frequency of errors
Temperature
Green
RollerDrive temperature OK.
Yellow
The temperature of the RollerDrive has reached the warning limit.
Red
The temperature of the RollerDrive has exceeded a critical value.
Power
Green
The RollerDrive is working within the specified power limits.
Yellow
The rated power of the RollerDrive has been exceeded.
Red
The power of the RollerDrive is > 120% of the rated power.
Frequency of errors
The frequency of the following errors is monitored within a specified time frame:
• Heavy running
• Stall timing
• Overvoltage
• Undervoltage
Green
Status of the RollerDrive OK.
Yellow
The number of errors within the specified time frame has reached the warning limit.
Red
The number of errors within the specified time frame has reached a critical limit.
The indicator lights are used purely for information purposes and do not result in the shutdown of the
RollerDrive.
The signals can be evaluated and processed via the connected control system.
Summary of Contents for RollerDrive EC5000 AI
Page 6: ......
Page 54: ...INSPIREDBY EFFICIENCY 2020 INTERROLL EN 03 2020 Version 2 4...