31
441 01 5003 01
Specifications are subject to change without notice
Model Specifications
Manufacturers Number (Mfr No -
See Rating Plate
)
ALL Models (H8UH5/MUF/HL)
Specifications
H8UH5050B12C2
MUF050W3C2
HL12H3TRC2
H8UH5075B12C2
MUF075W3C2
HL18H3TRC2
H8UH5100F14C2
MUF100W3C2
HL25H3TRC2
H8UH5125J20C2
MUF125W5C2
HL31H4TRC2
H8UH5140J20C2
MUF140W5C2
HL34H5TRC2
General
Input (Btuh)
Temp. Rise (
°
F/
°
C)
50,000
30--60/17--33
75,000
35--65/19--36
100,000
35--65/19--36
125,000
35--65/19--36
140,000
45--75/25--41
Electrical (Volts/Hz)
220/50
220/50
220/50
220/50
220/50
Rating Plate
6.1
6.1
6.1
11.5
11.5
Gas Type
Nat
Propane
Nat
Propane
Nat
Propane
Nat
Propane
Nat
Propane
Transformer Size (VA)
T’stat Heat Anticipator
40
.50
40
.50
40
.50
40
.50
40
.50
40
.50
40
.50
40
.50
40
.50
40
.50
Gas & Ignition
Std. Main Orifices (No/Size)
2/#42
2/#54
3/#42
3/#54
4/#42
4/#54
5/#42
5/#54
6/#42
6/#54
Gas Valve Honeywell
Regulation Type
VR8205S
SNAP
Manifold Press. (in wc)
3.5
10.0
3.5
10.0
3.5
10.0
3.5
10.0
3.5
10.0
Ignition Type/Series
Hot Surface
Combustion
Flue Outlet Size (Inches)
4
4
4
4
4
Limits & Controls
Thermal Sensor (
°
F)
Limit Control
300
See Parts List
300
See Parts List
300
See Parts List
300
See Parts List
300
See Parts List
Std. Pressure Sw. (Part No)
Press (Close)
Press (Open)
1014051
--0.57
--0.47
1014051
--0.57
--0.47
1014051
--0.57
--0.47
1014051
--0.57
--0.47
1014051
--0.57
--0.47
Furnace Control (Type)
Furnace Control On
(Timed--secs)
Off
Intergrated
30
72,120,168,216
Blower Data
Blower Size Inches (D x W)
Motor Type/H.P.
Cap. Mfd/Volts
Filter Type (600 FPM)
Filter Size (
″
) less than 1600 CFM
11--8
PSC/
1
/
2
7.5/370
Washable
------
11--8
PSC/
1
/
2
7.5/370
Washable
------
11--10
PSC/
1
/
2
7.5/370
Washable
------
11--10
PSC/
3
/
4
10/370
Washable
------
12--12
PSC/
3
/
4
10/370
Washable
------
1600 CFM and over*
------
------
------
16x25x1 (2)*
side return
s
20x25x1*
+
bottom return
16x25x1 (2)*
side return
s
20x25x1*
+
bottom return
Min. Cool Cap. (Tons)
Max. Cool Cap. (Tons)
1.5
3
1.5
3
2
3.5
3
5
3
5
Nat to Propane NAHA001LP
* Two side filter racks (left and right) required for upflow applications with 1600 CFM or greater. Side returns are not permitted with
horizontal furnace applications.
**Must be ordered from Service Parts.
+ Supplied
Conversion
1 in = 25.4 mm
1 in wc = 249.0 Pa