Appendix 4 Interfaces
Pin Signal
Name
Remarks
1
/STROBE
2–9 DATA
0–7
10
ACK
11
BUSY
12
PE
13
SELECT
14–15 Not
connected
16–17 GND
18
+5 VDC Ext
Max. 200 mA. Enabled by strap on P-2
19–30 GND
31
/INPRM
32
/ERROR
33-35
Not connected
36
/SLCTIN
37–38 GND
Housing
Refer to the installation instructions for the Parallel Interface Board
for further information.
Parallel Interface
Board (option)
The EasyCoder 501 E can optionally be fi tted with a parallel interface
board. The parallel port is addressed in Intermec Fingerprint
as device "centronics:". Select "centronics:" as the standard IN
port using the instruction SETSTDIO (by default, "uart1:" is std
IN port)
1
.
Interface Cable Connectors
Computer end:
Depends on type of host computer.
Printer end:
36-pin IEEE 1284B Centronics socket
"centronics:"
1
/. Intermec Shell either auto-
matically sets the correct stan-
dard IN and OUT port when
an application is selected or
prompts you to select one, see
Chapter 9.
230V