Connection for Raypak Heaters
The following connection procedure is for
the two wire-one function configuration
Raypak heater.
Connect two #14 gauge wires, designed
for use in hot environments, to the
two black wires on the panel-mounted
receiver.
Connect one end of either #14 gauge
wires from Step 1 to both the orange/
black and black/orange wires on the
Raypak heater.
Connect the remaining #14 gauge wire
from Step 1 to the yellow/black wire on
the Raypak heater.