![Intermatic MULTIWAVE PE653RC Programming And Usage Instructions Download Page 44](http://html1.mh-extra.com/html/intermatic/multiwave-pe653rc/multiwave-pe653rc_programming-and-usage-instructions_2077478044.webp)
www.intermatic.com
44
MultiWave Control System Programming and User Guide
&KDQJLQJD6HFRQGDU\&RQWUROOHUWR3ULPDU\
Follow this procedure to change a secondary remote to primary.
NOTE:
There can only be one primary controller in a given network.
1.
Press
P/S
and
ENTER
simultaneously to access
LEARN MODE
.
2.
Press
to scroll to the
CNTRL CONFIG
screen.
3.
On the primary controller, press
3 CONTROLLER SHIFT
. The controller
displays
PRESS BUTTON ON DEVICE TO INCLUDE INCLUDING
DEVICE
.
4.
On the secondary controller that you want to change to primary, press
3 RECV NET AND CFG
. The primary and secondary controllers restart
and then the following noti
fi
cations appear on the
PRIMARY
and
SECONDARY
controllers:
•
The
PRIMARY
controller:
INCLUDING DEVICE
appears, followed
by
SENDING NET INFO, SENDING SCENE INFO, SENDING CFG
INFO
. The controller then returns to the
CNTRL COPY
screen.
•
The
SECONDARY
controller:
WAITING FOR INCLUDE
appears. After data is moved from
the to the secondary controller,
SUCCESSFUL
appears and the controller returns to the
main screen.
5.
Make sure both controllers are returned to the main screens. The procedure is complete.
,QFOXGLQJD&RQWUROOHULQWRD7KLUG3DUW\1HWZRUN
The MultiWave controller is a Z-Wave compliant device that can be included in networks created by
other manufacturer’s Z-Wave compliant controllers. If applicable, follow this procedure to include the
MultiWave controller in another manufacturer’s controller network.
1.
Activate the replication function on the third party controller to transmit network information to the
MultiWave controller.
NOTE:
See the third party manufacturer’s instructions for further instructions.
2.
On the MultiWave controller, press
P/S
and
ENTER
simultaneously to access
LEARN MODE
.
3.
Press
to scroll to the
CNTRL CONFIG
screen.
4.
Press
2
to display the
CONTROLLER COPY
screen.
5.
Press
2
to receive network information for the MultiWave controller. The controller displays
WAITING FOR INCLUDE
, followed by
SUCCESSFUL
. The screen then reboots. The controller is
con
fi
gured as a secondary controller for the third party network.
([FOXGLQJD&RQWUROOHUIURPD7KLUG3DUW\1HWZRUN
To exclude a MultiWave controller from a third-party network, reset the MultiWave controller. Perform