ZeroWire Reference Guide
©2015 United Technologies Corporation
A
r
e
a
s
C
o
n
f
i
g
u
r
a
t
i
o
n
M
e
n
u
Option
Default
Function
Select Area to Configure
Area 1
Use the drop down menu to select which of the
4 areas to program.
Area Name
Blank
Each area can be configured with a custom 32
character name. The area name is displayed
wherever an area is referenced on the
ZeroWire system.
Area
T
ime
rs
Entry Time 1 (30-240)
Seconds
30
Provides time to enter into the premises to
deactivate the alarm system.
Exit Timer 1 (45 - 255)
Seconds
45
Provides time to exit the premise without
activating the alarm system.
Entry Timer 2 (30 - 240)
Seconds
0
If there is a second entry door that requires
more time to deactivate the alarm system.
Exit Timer 2 (45 -255)
Seconds
0
If there is a second exit door that requires more
time to leave.
Stay Enter Timer (30 - 240)
Seconds
30
When the system is armed to "STAY" this will
be the entry time to deactivate the alarm
system.
Area
O
ptions
Quick Away
Off
If enabled, the area can be armed in away
mode with a single press. When area is armed
via quick away mode, the closing user number
is the default user of 999.
Quick Stay Mode Disarm
Off
If enabled, this will allow the stay mode to be
disarmed by pressing the stay key on the
ZeroWire panel. If the system is in alarm a PIN
must be used.
Manual Panic
On
Enables or Disables the Keypad Panic
Manual Fire
On
Enables or Disables the Keypad Fire
Manual Auxiliary
On
Enables or Disables the Keypad Auxiliary
Force Arm With Bypass
Off
If enabled, the area can be armed even if
sensors are not ready. Any sensors that are not
ready will NOT be automatically be bypassed
and may cause an alarm condition because
they could still be in a not ready state once the
area becomes armed.
This option is overridden if the Force Arm With
Auto-Bypass is enabled.
Individual sensors can be made “force arm-able
without auto-
bypass” by leaving this area option
off, then enabling Forced Arm Enable in Sensor
options, and disabling Sensor Inhibit (Bypass)
in the Sensor Type Profile.