12BChapter 13: Alarm and event setup
TruVision NVR 71 User Manual
81
b) Specify which alarm outputs are triggered when an event occurs.
c) Select the cameras to be triggered when an external alarm is detected.
d) Select the PTZ camera function required in response to an external alarm.
Under
PTZ Linking
, enable the preset, preset tour or shadow tour to be triggered when
the alarm is detected and enter the preset, preset tour or shadow tour number.
7. If you want to copy the settings to other alarm inputs, select the desired alarm inputs under
“Copy to alarm”.
8. Click
Save
to save the settings.
Set up alarm outputs
You can connect the recorder to an alarm system, such as a siren or intrusion system, which is
then activated when an alarm is triggered. You can select how long the alarm signal remains
active as well as schedule when alarm outputs can be triggered.
“A” outputs are marked A for analog and are physical outputs of the recorder. “D” outputs are
marked as D for digital and are physical outputs on the IP cameras.
To set up an alarm output:
1. From the menu toolbar, click
Configuration
>
Remote Configuration
>
Alarm & Event
Setup
>
Alarm Output
.
2. Select the alarm output. Enter a name for it, if desired (the name cannot be copied).
3. Select a time out option between 5 seconds and 10 minutes, or select “Manual”.
The timeout setting lets you define how long an alarm signal remains active after the alarm
has ended. If you select
Manual
, the alarm signal remains active until it is acknowledged
(see “Manual trigger” on page 82).
4. Select the arming schedule for the alarm output.