12
SP1083600 Motor-Driven Blocking Device EasyLock Installation Manual
Figure 8: Connecting several blocking devices in series
Commissioning
When impressing the operating voltage on the blocking device will open up in
any case independent from the status of the inputs.
Functional check:
• Close and open the blocking device when the door is closed. In doing so,
check the following functions:
- Closing or opening time maximum about 1/2 second.
- The locking bolt must neither contact nor interlock on the counterpart. The
locking bolt extends without several locking trials.
- The locking bolt can extend at full length since otherwise it would open up
again after several locking trials.
• If the functionality is incorrect then check the wiring on the basis of the signal
descriptions and the examples for switching on described in