Contact information#1

 

Introduction#1

 

Compatibility#1

 

Account creation#1

 

Installation#2

 

Power up#3

 

GSM phone test (module registration)#3

 

Control panel settings that change automatically with 

HSPA 3G module#3

 

Troubleshooting: Module Status Information#3

 

Troubleshooting: LEDs#4

 

LED patterns for the various module states (modes)#6

 

Improving wireless signal strength#6

 

Interactive menus#6

 

Walking customer through new user setup on the web#9

 

Specifications#10

 

Regulatory information#10

 

Contact information 

www.utcfireandsecurity.com

 o

www.interlogix.com

 

For customer support, see 

www.interlogix.com/customer-

support

  

© 2013 UTC Fire & Security Americas Corporation, Inc. 

Interlogix is part of UTC Climate Controls & Security, a unit of 

United Technologies Corporation. All rights reserved. 

For additional information and support on Alarm.com products 

and services, please visi

www.alarm.com/dealer

 or contact 

Alarm.com technical support at 1-866-834-0470. 

Copyright © 2013 Alarm.com. All rights reserved. 

Introduction 

The HSPA 3G module (part numbers 600-1048-XT-ZX-TM , 

600-1048-XT-ZX-AT AND 600-1048-XT-ZX-RG) for Simon XT 

and XTi enables

 

wireless reporting of all alarms and other 

system events from the

 

Simon XT and XTi control panels using 

an all-digital, HSPA wireless

 

(cellular) network. The module 

can be used as

 

the primary communication path for all alarm 

signaling, or as a backup to a

 

telephone line connection to the 

central monitoring station. The

 

wireless alarm signaling and 

routing service is operated by

 

Alarm.com.

 

The V4 module also 

features integrated support for Alarm.com’s emPower

TM 

solution with built-in Z-Wave capabilities.

 

The module interfaces with the Simon XT and XTi panel 

boards, fits into a special compartment inside the

 

panel, and is 

powered by the control panel and panel battery. 

Compatibility

 

The V4 module with firmware version 151 & up is compatible 

with Simon XT and XTi panels. Older versions of the 

Alarm.com module, including versions of the V4 module with 

previous firmware versions are not compatible with the Simon 

XTi. 

Account creation  

Before installing an Alarm.com HSPA 3G Module in a Simon 

XT or XTi system, a new customer account needs to be 

created with Alarm.com. We recommend creating the account 

at least 24 hours in advance of installation to ensure that the 

radio is activated prior to installation. 

To activate an account go to www.alarm.com/dealer and login. 

Under the 

“Customers” heading at the top left of the page click 

on “Create New Customer”. You will need the following 
customer information to create the account: 

• 

Customer Name  

• 

Customer Address  

• 

Customer Phone Number 

• 

Customer E-mail 

• 

Preferred login name for the customer  

• 

Alarm.com Radio Serial Number 

At the end of the account creation process you will be able to 

print a Welcome Letter for the customer that has their login 

information and temporary password for the Alarm.com 

website. 

 

Summary of Contents for Simon XTi

Page 1: ...e used as the primary communication path for all alarm signaling or as a backup to a telephone line connection to the central monitoring station The wireless alarm signaling and routing service is operated by Alarm com The V4 module also features integrated support for Alarm com s emPower TM solution with built in Z Wave capabilities The module interfaces with the Simon XT and XTi panel boards fit...

Page 2: ...aw only 10 mA on average Avoid mounting the panel in areas with excessive metal or electrical wiring such as furnace or utility rooms Leave 12 to 18 in of open space around the module antenna Do not install the control panel and module in a basement or other below ground location Doing so will negatively impact HSPA signal strength Tools and supplies needed You will need the following tools and su...

Page 3: ...1 2 The panel will display GSM Comm Test in progress to indicate the test has been initiated To perform the phone on a Simon XTi 1 Press the Status Settings icon on the lower right of the home screen 2 Scroll Down and press Programming 3 Enter the installer code default 4 3 2 1 then OK 4 Press System Tests 5 Press Comm Test The panel will display GSM Comm Test in progress to indicate the test has ...

Page 4: ...le firmware version e g 4152a 3 Key 15 digit SIM card number 5 Key Wireless signal strength level and module status or error if any The panel will display bars for the signal level 0 to 5 and a number 2 to 31 followed by the Mode it is in See GSM Module Statuses on Table 1 6 Key Battery voltage as read by the module to two decimal places and the AC power status e g Battery 6 79v AC Power OK 8 Key ...

Page 5: ...arious possibilities Table 5 Z Wave LED status indicators LED 2 LED 5 Device status or error Description 4 blink Add mode lasts 120 seconds or until a device is added In this mode you can add a device to the local Z Wave network Devices cannot be added to a network if they are already a part of a network 2 blink Delete mode lasts 120 seconds or until a device is deleted In this mode you can delete...

Page 6: ...imal wireless signal strength Install the module above ground level as high up as possible within the structure Install the module near or adjacent to an outside facing wall of the structure Do not install the module inside a metal structure or close to large metal objects or ducts Make sure to follow the antenna positioning guidelines that are included with the antenna Certain antennas must be or...

Page 7: ... Interactive Services Scroll up to Interactive Services and press OK Sensor Reporting Test This menu is used to automate the process of confirming that all sensors report correctly to the Central Station It will put the account on test and request the list of sensors that did not report correctly It is available only to installers who have integrated their sensor testing process with the Central S...

Page 8: ...en activated or request an Installer Peek In Now to test image capture Delete1 Delete Image Sensors from the panel Set Dealer Logo Send the dealer logo to the panel and touch screen Only available for dealers who have set up this feature with Alarm com Weather Update Request a Weather Update if the weather forecast is not showing on the XTi touch screen To speed up the process stay in Programming ...

Page 9: ...o a different Z Wave network before you can learn it into the GSM module Update 2WTTS Press Update 2WTTS to force an update of the thermostat lights or locks information shown on the touch screen 2WTTS Note that these updates may take several minutes to complete Thermostats View thermostat data and update remove thermostats from display on the panel and touch screens Lights Update the lights list ...

Page 10: ...o an outlet on a circuit different from that which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body Under Industry Canada re...

Reviews: