xGen Lite Installation and Programming Guide
13
• Mains reporting delay, 3600 s maximum
• User code required, enabled
• Armed display, always
• Alarm list, disabled
• Inhibit includes, all allowed except engineer reset, which must be disabled
• Pending alarms, enabled
• Swinger shunt ≥ 3
• Report restore, on ACK
• Line fault, enabled per path used
• Line fault delay, 0 s
Refer to xGenLite Reference Manual for additional features, accessible at level 3.
For EN 50131-3 & T031, it is required to apply the following supervision settings
for wireless expanders:
• Short supervision: 20 minutes
• Long supervision: 2 hours
• Smoke supervision: 4 hours
Caution:
When any option, any additional function or any additional zone type in
this section does not comply with the EN 50131 requirements, the EN 50131
compliance label must be removed from the system.
Optional Functions
• Detection of storage device – failure
• Detection of low output voltage
EN 50131 Compliance Precautions
Installation
In order to install an EN 50131 compliant system, please make sure that all
system components are EN 50131 compliant.
Programming
Make sure that all system settings are in line with regulatory compliance
guidelines.
Size of log / event history
For full EN 50131
Grade 2
compliance, the system must store at least
500 events.
Marking
It is only allowed to mark the system with the EN 50131 compliance label, if the
following requirements are met:
• All system components are EN 50131 compliant.
• All settings are done according to EN 50131.
Summary of Contents for NXG-4
Page 1: ...xGen Lite Installation and Programming Guide P N 466 5545 EN REV C ISS 08OCT19 ...
Page 4: ......
Page 49: ...xGen Lite Installation and Programming Guide 37 ...
Page 109: ...xGen Lite Installation and Programming Guide 97 Web Page ...
Page 116: ...104 xGen Lite Installation and Programming Guide Next go to Schedules and tick Holidays 1 ...
Page 132: ...120 xGen Lite Installation and Programming Guide Webpage ...
Page 168: ......