12
xGen Lite Installation and Programming Guide
#
SIA code CID code Function
157
YQ
R351
Power Supply Restore
EN 50131-3 and EN 50136-2 Compliancy
In order to be compliant with the technical specification EN 50131-3 (Alarm
systems
– Control and indicating equipment), the following guidelines must be
taken into account:
• The tamper of the warning device should be connected to a 24-hour zone
input.
• Overriding is not supported with xGenLite. In case a zone is faulted, one shall
bypass the zone manually before arming or verify the zone and clear the fault.
See user instructions.
• Hold-up zones are not allowed to be set for bypass.
• Zone isolation is not supported.
• EN 50136-2 (Alarm transmission systems and equipment – Part 2:
Requirements for Supervised Premises Transceiver (SPT):
- Upon configuring alarm transmission path and remote connection details,
default user/installer keys shall be changed.
- Minimum PIN length is 6 digits.
Options Affected by EN 50131 Regulations
EN 50131 Grade 2 Required settings
The following options and values are mandatory for EN 50131-1 Grade 2
regulations.
• Period, 24 h for every path to meet ATS Class 2, 4 h for the IP path to meet
Class 4.
• View Areas and Control Areas settings are identical
• Buzzer silent, never
• Quick set, off
• Function keys, all set to None
• User group options, 25. No OP/CL reports option set to No
• Inhibit, set to No for all zones with type 5. Panic, 6. 24H
• Swinger shunt, set to Yes for all zones
• ACK on keypad, set to None for all zones with type 9. Keyswitch
• Entry time, 45 s maximum
• Entry alarms, Instant
• Active, set to No for all schedules.
• Activation, internal and external siren 90 to 900 s
• Delay time, external siren 600 s maximum
• Armed display, 30 s maximum
Summary of Contents for NXG-4
Page 1: ...xGen Lite Installation and Programming Guide P N 466 5545 EN REV C ISS 08OCT19 ...
Page 4: ......
Page 49: ...xGen Lite Installation and Programming Guide 37 ...
Page 109: ...xGen Lite Installation and Programming Guide 97 Web Page ...
Page 116: ...104 xGen Lite Installation and Programming Guide Next go to Schedules and tick Holidays 1 ...
Page 132: ...120 xGen Lite Installation and Programming Guide Webpage ...
Page 168: ......