NX-1700E Card Reader 

17 

IX. 

GLOSSARY 

 

TERM 

DESCRIPTION 

Alternative Mode 

Alternative mode is an optional scan method, as opposed to the default Legacy mode (see below).  
The card is to be continuously held at the reader for a specified number of beeps.   Example:  Hold 
the card at the card reader’s sensor for a total of 2 beeps.  This is a “double beep” in the Alternative 
mode.    This method becomes available when Location 272, Segment 1, Option 6 is disabled. 

Double 
Beep……………….

 

An audible indicator (beep, beep). 

Double Beep Scan………..

 

When a user card is scanned and held at the reader for 2 beeps, the reader will perform the functions 
as programmed in Location 241, Segment 4. 

Legacy Mode………………

 

Legacy mode is used to describe the default operation of the card reader’s scanning method.  This 
mode uses the same scan methods as prior versions of the card reader modules. Example: Pass a 
user card by the reader’s sensor, remove it from the field, then pass the card by the reader’s sensor 
once again during the time programmed in Location 244, Segment 1.  This is a “double scan” in the 
legacy mode. 

Request To Exit 
(RTE)……

 

A zone can be programmed to monitor an open door.  The RTE activates the onboard open collector 
output and sends a message on the buss. 

Scan……………………….

 

To “present” or pass a card or FOB within sensing range of the card reader module. 

Single Beep………………..

  An audible indicator (beep). 

Single Beep Scan…………

 

When a user card is scanned and held at the reader for 1 beep, the reader will perform the functions 
as programmed in Location 241, Segment 3. 

Triple Beep………………...

  An audible indicator (beep, beep, beep). 

Triple Beep Scan………….

 

When a user card is scanned and held at the reader for 3 beeps, the reader will perform the functions 
as programmed in Location 241, Segment 5. 

 

X. 

FCC INFORMATION 

This device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions: 

1. This device may not cause harmful interference. 

2. This device must accept any interference received, including interference that may cause undesired operation. 

3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s 
authority to operate the equipment. 

FCC ID: CGGNX-1700E 
 
 

XI. 

UNDERWRITERS LABORATORIES INFORMATION 

 

The NX-1700E module has received UL listing: 

 

UL294  Access Control Systems Units 

 
 

XII. 

SPECIFICATIONS 

DIMENSIONS

 

Approx. 1.5"W x 4.5"L x 1"D with 6’ cable 

OPERATING POWER

 

12 VDC, Supplied by NX-6, NX-8, NX-8E, or NX-320E 

CURRENT DRAW

 

40mA  Standby with Green LED 

 110mA 

Maximum 

OPERATING TEMPERATURE

 

-31 to +151 degrees F 

 

5 to +66 degrees C 

 

SHIPPING WEIGHT

 

< 1 lb. 

 
 

 

1420 N. MAIN STREET;  GLADEWATER, TEXAS  75647 

 

Main 800-727-2339 

Technical 

Support 

888-437-3287 

Outside the US 

903-845-6941 

Sales & Literature 

800-547-2556 

Summary of Contents for NetworX NX-1700E

Page 1: ...m Symbol Legend Warning Indicates a procedure practice condition or statement that if not strictly observed could result in personal injury This symbol indicates electrical warnings and cautions Caution Indicates a procedure practice condition or statement that if not strictly observed could result in damage to or destruction of equipment or property This symbol indicates general warnings and caut...

Page 2: ...rtition 8 Location 243 Programming the Zones 9 Location 244 Programming the Various Reader Timers 9 Location 245 Resetting the Reader Address 9 Location 246 Programming the Access Options 9 Location 247 Programming the Opening Time for Schedule 1 10 Location 248 Programming the Closing Time for Schedule 1 10 Location 249 Programming the Days for Schedule 1 10 Locations 250 270Programming the Sched...

Page 3: ...R Absolute maximum 14 volts 25mA This is a low current output and must not be used to directly energize high current door openers III ENROLLING The NetworX control panels have the ability to automatically find and store in memory the presence of all keypads zone expanders wireless receivers output modules and any other device on the keypad buss This allows these devices to be supervised by the con...

Page 4: ... that segment awaiting a valid entry To Enter a Location location The Armed LED will flash If the location is valid the Armed LED will extinguish the Ready LED will illuminate and the zone LED s will show the data for the first segment of this location To Change Location Data changed data The Ready LED will flash to indicate a data change in process and will continue until the data is saved The ne...

Page 5: ...ion 242 Segment 1 Option 1 page 8 It is recommended that only one reader on the system be enabled to modify user cards and that this reader be located near a keypad This reader will transfer information to all other readers in the system once programming is finished Once a reader is enabled to modify users it must be placed into one of the following five modes 1 Add One User 2 Add Multiple Users w...

Page 6: ... is not already in the system it will be added and mapped to the entered user number and LED1 will continue flashing indicating that the next user card can be scanned for the next user number 2 If the card is already in the system the reader will triple beep and LED1 will continue flashing the user number is not incremented in this case Continue scanning user cards until the desired number of card...

Page 7: ...OCATIONS SCAN METHODS Legacy mode is default Alternative mode is shown below in brackets Refer to Location 242 Segment 1 on page 8 and the Glossary on page 17 for explanation LOCATION 0 PROGRAMMING THE SCAN FUNCTIONS 3 segments of binary data Location 0 is used to select the particular function s that are activated when a card is scanned More than one function may be selected If more than one func...

Page 8: ... Beep Scan Function This location only needs to be programmed if Location 0 Segment 2 Option 7 is set Use the above table Default is 3 Segment 5 Single Scan Hold Function Triple Beep Program the X 10 function that is performed when a card is scanned and held at the reader for the duration of the 2 Scan Hold Time three beeps Location 244 Segment 1 programs the length of time between beeps The descr...

Page 9: ...s 111 169 Seg 4 Opt 3 LOCATION 244 PROGRAMMING THE VARIOUS READER TIMERS 4 segment of numerical data Segment 1 Scan Time Enter the amount of time required to hold a card between beeps to activate the functions programmed in Location 0 Segments 2 and 3 This timer is timed in 1 100 second increments from 0 to 2 55 seconds Default is 100 1 second Segment 2 Relay Active Time Enter the amount of time t...

Page 10: ...hedule 1 Default is 0 LOCATION 249 PROGRAMMING THE DAYS FOR SCHEDULE 1 1 segment of binary data LED1 On if schedule is active on Sunday LED2 On if schedule is active on Monday LED3 On if schedule is active on Tuesday LED4 On if schedule is active on Wednesday LED5 On if schedule is active on Thursday LED6 On if schedule is active on Friday LED7 On if schedule is active on Saturday LED8 On if sched...

Page 11: ...ated If the LED is on the card is active Each segment has 8 LEDs corresponding to the 8 possible user cards Example Segment 4 LED2 indicates that user card 26 is active SEG USER CARDS SEG USER CARDS SEG USER CARDS SEG USER CARDS SEG USER CARDS 1 1 8 4 25 32 7 49 56 10 73 80 13 97 104 2 9 16 5 33 40 8 57 64 11 81 88 14 105 112 3 17 24 6 41 48 9 65 72 12 89 96 15 113 120 LOCATION 284 PROGRAMMING ACT...

Page 12: ...he Disarm function to the control panel 5 On to send Auxiliary Function 1 to the control panel 6 On to send Auxiliary Function 2 to the control panel 7 On to broadcast an X 10 function Loc 241 for programming 8 On to send an RTE and activate the onboard open collector output 1 240 8 RESERVED 241 8 X 10 ADDRESS Seg 1 MODULE NUMBER 0 Seg 2 HOUSE CODE 0 NX 1700E Card Reader 12 see chart X 10 ADDRESS ...

Page 13: ...board open collector output only triggers during a close schedule 6 On if Forced Entry Alarm is logged 7 On if access allowed without an RTE 8 On if relay operates normally during off schedule outside of regular operating hours Seg 2 SCHEDULES FOR ONBOARD OPEN COLLECTOR OUTPUT 1 On if driver follows Schedule 1 2 On if driver follows Schedule 2 3 On if driver follows Schedule 3 4 On if driver follo...

Page 14: ...10 CLOSING TIME FOR SCHEDULE 4 Seg 1 Hour of Closing Time 24 hr format 20 8 PM Seg 2 Minutes after Hour of Closing 0 258 10 DAYS FOR SCHEDULE 4 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active o...

Page 15: ... is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 271 11 HOLIDAYS IN JANUARY 8 max No holidays _ _ _ _ _ _ _ _ 11 HOLIDAYS IN FEBRUARY 8 max No holidays _ _ _ _ _ _ _ _ 272 273 11 HOLIDAYS IN MARCH 8 max No holidays _ _ _ _ _ _ _ _ 274 11 HOLIDAYS IN APRIL 8 max No holidays _ _ _ _ _ _ _ _ 275 11 HOLIDAYS IN MAY 8 max No holidays _ _ _ _ _ _ _ _ 2...

Page 16: ...NX 1700E Card Reader 16 LOC PG DESCRIPTION DEFAULT YOUR DATA 285 11 CODE ENTRY LOGGING PARTITION 0 ...

Page 17: ...FOB within sensing range of the card reader module Single Beep An audible indicator beep Single Beep Scan When a user card is scanned and held at the reader for 1 beep the reader will perform the functions as programmed in Location 241 Segment 3 Triple Beep An audible indicator beep beep beep Triple Beep Scan When a user card is scanned and held at the reader for 3 beeps the reader will perform th...

Page 18: ...Main Fax 903 845 6811 www utcfireandsecurity com Revision B Mar 2012 ...

Reviews: