User’s Manual of NS2503-24P/2C
160
Switch(config)#
show vlan pvid
Port | PVID
-----------+-------
Port1 | 1
Port2 | 1
Port3 | 1
Port4 | 1
Port5 | 1
Port6 | 1
Port7 | 1
Port8 | 1
Port9 | 1
Port10 | 1
Trk1 | 1
vlan filter
Description:
Set ingress filter rules.
Syntax:
vlan filter (enable | disable) (enable | disable) LIST
Parameters:
(
enable
|
disable
) specifies the non-members packet will be forwarded or not. If set enable, forward only packets with VID
matching this port's configured VID.
(
enable
|
disable
) specifies the untagged frame will be dropped or not. If set enable, drop untagged frame.
show vlan filter
Description:
Show VLAN filter setting.
Syntax:
show vlan filter [LIST]
Parameters:
[LIST] specifies the ports to be showed. If not entered, all ports’ filter rules will be showed.
Switch(config)#
show vlan filter
Port | Rule 1 | Rule 2
Filter (nonmbr) (untag)
-----------+------------+---------
Port1 | Drop | Forward
Port2 | Drop | Forward
Port3 | Drop | Forward
Port4 | Drop | Forward
Port5 | Drop | Forward
Port6 | Drop | Forward
Port7 | Drop | Forward
Port8 | Drop | Forward
Port9 | Drop | Forward
Port10 | Drop | Forward
Trk1 | Drop | Forward