P/N 146251999-4 (ML) • REV D • ISS 12MAR13 

Note: 

Using the pry-off tamper has not been evaluated by 

UL. 

4.  Wire the detector (see Figures 3 and 7). 

UL installations: 

All wiring must be made according to 

National Electrical Code, NFPA70, and CSA C22.1, 
Canadian Electrical Code Part I, Safety Standards for 
electrical Installations. 

5.  Select the desired jumper and DIP switch settings (see 

Figure 5). See “Jumper settings” below for more 
information. 

6.  Remove the blinders and add the stickers, if required (see 

Figure 6 for an example). 

7.  For ceiling-mount applications that require a 90° coverage 

use the SB01 swivel-mount bracket. 

Note: 

Using the swivel-mount bracket has not been 

evaluated by UL. Ceiling mount application has not been 
evaluated by UL. 

8.  Close the cover. 
9.  Insert the screw and place the custom insert. 
For EN 50131 Grade 3 installations, do not use mounting 
position B. 

Jumper settings 

See Figure 5 for the jumper locations in the detector. 

J1: Mode jumper 

Note: 

Bi-curtain jumper functionality is available in EV1116 

with firmware version 1.13 or later, and in EV1116AM with 
firmware version 1.21 or later. 
On: BI-curtain mode. In this mode an extra level of processing 
is applied to provide enhanced stability in the presence of false 
alarm hazards. Bi-curtain is used to reduce the possibility of 
false alarms. It looks for signal verification and requires the 
intruder to be seen in two curtains.  
This mode is not suitable for single curtain applications. 
Off: Standard mode (default). This mode is suitable for most of 
the wide angle and single curtain applications. The mode must 
be used in EN 50131 compliant installations. 

J3 and J4: Dual loop setting 

This sets the alarm and tamper relays. It allows you to connect 
the detector to any control panel. Use jumpers 3 and 4. See 
Figure 7. 
Use Remote Test (RT) to test the detector from the control 
panel. The detector will activate the Alarm relay if the test 
result is positive, and the AM relay if the test result is negative. 

J6: Polarity setting of the control voltage (CV) 

On (factory default):  

• 

The detector is in Day mode (system disarmed) when the 
D/N input is connected to GND (terminal 1) 

• 

The detector is in Night mode (system armed) when the 
D/N input is connected to +12 V (terminal 2) 

• 

The detector is in Walk Test Off mode (LEDs are disabled) 
when the WT input is connected to GND (terminal 1) 

• 

The detector is on Walk Test On mode (LEDs are 
enabled) when the WT input is connected to +12 V 
(terminal 2) 

Off:  

• 

The detector is in Day mode (system disarmed) when the 
D/N input is connected to +12 V (screw terminal 2).  

• 

The detector is in Night mode (system armed) when the 
D/N input is connected to GND (terminal 1).  

• 

The detector is in Walk Test Off mode (LEDs are disabled) 
when the WT input is connected to +12 V (terminal 2). 

• 

The detector is on Walk Test On mode (LEDs are 
enabled) when the WT input is connected to GND 
(terminal 1). 

D/N and WT functionality 

The D/N input: 

• 

Controls the LED functionality together with the WT input. 

• 

Resets the alarm memory 

• 

Controls the AM relay functionality during the NIGHT 
mode together with SW1. 

The WT input controls the LED functionality together with the 
D/N input. 
When the detector is in the Day mode and Walk Test On 
mode, the LEDs of the detector can be activated. See “LED 
indication” on page 5 for more 
information. 
During the Night mode the LEDs are always switched off. 
If a PIR intruder alarm if detected in the Night mode and the 
detector switches back to Day mode, the red LED starts 
flashing to indicate an alarm in memory. 
The alarm memory is reset by switching the detector to Night 
mode. 

DIP switch settings 

Factory default: 

ON

5

4

3

2

1

 

SW 1: When to signal AM (anti-masking) or TF (technical 
fault) output 

On: Signals AM or TF only when the system is in Day mode 
(factory default). 
Off: Always signals AM or TF during Day and Night mode. 

SW 2: AM sensitivity 

On: Selects a higher level of AM sensitivity. AM relay reacts 
within 6 seconds. 
Off: Selects the standard AM sensitivity. AM relay reacts within 
12 seconds (factory default). 

SW 3: Resetting the AM/TF output 

The system will only reset an AM alarm if it has ensured that 
the cause of the AM alarm has been removed. If the AM 
circuitry cannot return to its original reference levels, then 
either the detector is still masked or possibly has been 
damaged. The owner should then visually check that the 
detector is still fully functional. 
On: Resets the AM or TF status 40 seconds after a PIR alarm. 
Off: Resets the AM or TF status after a PIR alarm when the 
system is in Day and Walk Test mode. The yellow LED will 
blink quickly. When the system is in Night status, the yellow 
LED will turn off and the system is reset (factory default).  

SW 4: Signaling AM or TF output 

On: Signals AM on both the AM and Alarm relays. Signals TF 
on the AM relay only (EN 50131). 
Off: Signals AM and TF on the AM relay (factory default). 

Summary of Contents for EV1116 Series

Page 1: ...3 4 1 2 m 3 ft 11 in 4 m 13 ft 1 in 16 52 ft 6 in 0 m optimum 2 4 m 7 ft 10 in 16 m range 52 ft 6 in 2 m 0 m 2 m 6 ft 6 in 4 m 13 ft 1 in 6 m 19 ft 8 in 8 m 26 ft 2 in 2 m 6 ft 6 in 4 m 13 ft 1 in 6...

Page 2: ...2 32 P N 146251999 4 ML REV D ISS 12MAR13 5 EV1116 J1 J6 J3 J4 EV1116AM J1 J3 J4 J6 6...

Page 3: ...The EV1116 series includes the EV1116 and EV1116AM PIR motion sensors They have a patented mirror pyro and signal processing technology Note EV1116AM has not been evaluated by UL Installation guideli...

Page 4: ...nnected to GND terminal 1 The detector is on Walk Test On mode LEDs are enabled when the WT input is connected to 12 V terminal 2 Off The detector is in Day mode system disarmed when the D N input is...

Page 5: ...g UL Installations Weight 150 g IP IK rating IP30 IK02 Regulatory information Manufacturer UTC Fire Security Americas Corporation Inc 1275 Red Fox Rd Arden Hills MN 55112 6943 USA Authorized EU manufa...

Page 6: ...l i Figur 6 7 Til loftsmontering med 90 graders anvendelse benyttes SB01 svingmonteringskonsol 8 Luk frontl gen 9 Is t skruen og anbring d kpladen Til EN 50131 Grade 3 installationer m monteringsposit...

Page 7: ...ard SW 4 AM eller TF signal udsendes Til Viser AM p b de AM og alarmrel et Viser TF kun p AM rel et EN 50131 Fra Viser AM og TF p AM rel et fabriksstandard SW 5 Indstilling af LED Til Aktiverer altid...

Page 8: ...m Abstand von 1 80 m bis 3 m vom Boden an der Wand Verwenden Sie f r eine flache Montage mindestens zwei Schrauben DIN 7998 in den Positionen A Verwenden Sie f r eine Eckmontage Schrauben in den Posit...

Page 9: ...abe signalisiert werden sollten Ein Signalisiert AM oder TF nur wenn sich das System im Tagbetrieb unscharf Werkseinstellung befindet Aus Signalisiert AM oder TF immer im Tag und Nachtbetrieb SW 2 AM...

Page 10: ...auf eines gleichwertigen neuen Ger ts an Ihren H ndler vor Ort zur ck oder geben Sie es an einer entsprechend gekennzeichneten Sammelstelle ab Weitere Informationen hierzu finden Sie auf der folgenden...

Page 11: ...los puentes 3 y 4 Consulte la figura 7 Utilice la prueba remota RT para realizar una prueba del detector desde el panel de control El detector activar el rel de alarma si la prueba da resultados posi...

Page 12: ...ado Alarma PIR de intruso Abierto alarma Autom ticamente despu s de 3 s PIR AM LED rojo LED amarillo Rel de alarma Rel de AM Restablecimiento Inicio Cerrado Cerrado Autom ticamente despu s de 60 s Ten...

Page 13: ...den desechar como residuos urbanos no clasificados en la Uni n Europea Para que se pueda realizar un reciclaje adecuado devuelva este producto a su representante de ventas local al comprar un equipo n...

Page 14: ...T tulo ohjaa ledien toimintaa yhdess D N tulojen kanssa Kun tunnistin on p iv tilassa ja K velytesti p ll tilassa Ilmaisimen ledit voidaan aktivoida Lis tietoja on kohdassa Ledien merkitys alla Y tila...

Page 15: ...valmistusedustaja UTC Fire Security B V Kelvinstraat 7 6003 DH Weert Alankomaat Sertifiointi 2002 96 EC WEEE direktiivi T ll symbolilla merkittyj tuotteita ei saa h vitt Euroopan Unionin alueella tal...

Page 16: ...pour les installations conformes EN 50131 J3 et J4 Configuration de la boucle double La boucle double permet de r gler les relais d alarme et d autoprotection Elle permet de connecter le d tecteur to...

Page 17: ...usion IRP Ouvert alarme Automatiquement apr s 3 s IRP AM T moin rouge T moin jaune Relais d alarme Relais AM R initialisation D marrage Ferm Ferm Automatiquement apr s 60 s Basse tension Ouvert alarme...

Page 18: ...diretta Forti correnti d aria in prossimit del rilevatore Fonti di calore nel campo di rilevazione del rilevatore Animali nel campo di rilevazione del rilevatore Oscuramento del campo di rilevazione...

Page 19: ...copertura On possibile attivare i LED del rilevatore Per ulteriori informazioni vedere Indicatori LED pi sotto Nella modalit Notte i LED sono sempre spenti Se viene rilevato un allarme anti intrusion...

Page 20: ...Americas Corporation Inc 1275 Red Fox Rd Arden Hills MN 55112 6943 Stati Uniti Rappresentante autorizzato per l UE UTC Fire Security B V Kelvinstraat 7 6003 DH Weert Paesi Bassi Certificazione IMQ Cer...

Page 21: ...beelding 7 Gebruik zelftest RT om de detector te testen vanaf de centrale De detector activeert het alarmrelais als het testresultaat positief is en activeert het AM relais als het testresultaat negat...

Page 22: ...isch na 25 sec Lage spanning Open Alarm Correcte spanning toepassen PIR inbraakalarm Open Alarm Automatisch na 3 sec PIR AM Rode LED Gele LED Alarm relais AM relais Opnieuw instellen Opstarten Geslote...

Page 23: ...t p klebemerker hvis det er n dvendig se eksempelet i figur 6 7 Bruk SB01 dreiemonteringsbraketten for takmonteringer som krever en 90 graders dekning 8 Lukk dekselet 9 Sett inn skruen og sett innlegg...

Page 24: ...kinnstilling SW 4 Signalisere AM eller TF utgang P Signaliserer AM p b de AM og Alarmrel ene Signaliserer TF kun p AM rel et EN 50131 Av Signaliserer AM og TF p AM rel et fabrikkinnstilling SW 5 Still...

Page 25: ...o 9 8 stopy od pod ogi W przypadku monta u p askiego zastosowa co najmniej dwie ruby DIN 7998 umieszczaj c je w pozycji A W przypadku monta u naro nego u y rub w pozycji B lub C rys 3 Aby zamontowa za...

Page 26: ...y cznie w sytuacji kiedy otrzyma potwierdzenie o usuni ciu alarmu AM Je li obw d AM nie mo e powr ci do wyj ciowych poziom w odniesienia oznacza to e czujka jest nadal maskowana lub zosta a uszkodzona...

Page 27: ...V1116 e EV1116AM PIR Estes sensores apresentam uma tecnologia patenteada de processamento de sinais espelho e pirotecnologia Nota os modelos EV1116AM en o foram avaliados pela UL Passos de instala o A...

Page 28: ...ando a entrada WT est ligada a 12 V terminal 2 Off Desligado O detector est no modo Dia sistema desarmado quando a entrada D N est ligada a 12 V terminal de parafuso 2 O detector est no modo Noite sis...

Page 29: ...ima LED ligado 11 5 mA 24 mA Altura da instala o 1 8 m a 3 0 m Velocidade ao alvo 30 cm s a 3 m s 20 cm s a 3 m s Alarme NC Caracter sticas do rel de tamper 80 mA 30 VDC 80 mA 30 VDC Tamper de remo o...

Page 30: ...indre n 50 cm is r endast AM detektorer Installera detektorn Figur 7 anslutning Nr Beskrivning 1 Standardanslutning fabriksinst llning 2 Anslutning f r dubbelbalanserad slinga Nr Beskrivning CP Centra...

Page 31: ...TF utg ngen Systemet terst ller endast ett AM larm om det har s kerst llt att orsaken till AM larmet har tg rdats Om AM kretsarna inte kan terg till de ursprungliga referensniv erna r detektorn anting...

Page 32: ...tt inte sk rma av detektorns bevakningsomr de genom att placera f rem l framf r detektorn Information om regler och f reskrifter Tillverkare UTC Fire Security Americas Corporation Inc 1275 Red Fox Rd...

Reviews: