Maximum switch current 

0.5 A 

Contact dimensions 

Ø24 x 28.6 mm 

Magnet dimensions 

Ø24 x 39.7 mm 

Borehole diameter 

19.1 mm 

Operating temperature 

−40 to +65°C 
EN 50131 Class II: −10 to +55°C 

Regulatory information 

Manufacturer 

UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, 
USA 

Authorized EU manufacturing representative: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Environmental class 

IP68 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR 
SALE TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 
PRODUCTS, INCLUDING ANY 

“AUTHORIZED 

DEALER” OR “AUTHORIZED RESELLER”, IS 
PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 

For more information on warranty disclaimers 
and product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

Certification 

 

 

EN50131-2-6: 2008 

Security Grade 2, Class II 

Tested and certified by Applica Test & 
Certification, Norway 

European Union 
directives 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of the Directive 
2014/30/EU and/or 2014/35/EU. For more 
information see www.utcfireandsecurity.com or 
www.interlogix.com.

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European 
Union. For proper recycling, return this product 
to your local supplier upon the purchase of 
equivalent new equipment, or dispose of it at 
designated collection points. For more 
information see: 
www.utcfssecurityproducts.eu/recycle/ 

Contact information 

www.utcfireandsecurity.com or www.interlogix.com 

For customer support, see www.utcfssecurityproducts.eu 

DE: Installationsanleitung 

Bezeichnung 

Bei der DC107-

Serie handelt es sich um Magnetkontakte für 

die Einbaumontage, die mit einer Einbruchmeldeanlage 
verbunden werden können. Die DC107-Serie kann in 
ferromagnetischen Umgebungen 

verwendet und in Türen 

eingebaut werden. Unterschiede in der DC107-Serie 
entnehmen Sie bitte den „Technische Daten“ unten. 

Montage 

Der Magnetkontakt und der Magnet sollten direkt 
gegenüberliegend montiert werden. Wählen Sie die 
gewünschten Montagepositionen aus und bohren Sie 
entsprechende Löcher. Montieren Sie den Magneten und den 
Kontakt in den Löchern. 

Während der Installation müssen die Schaltabstände 
individuell bestimmt werden. 

Wenn die Installation abgeschlossen ist, muss die elektrische 
Funktion de

s Magnetkontakts überprüft werden (z. B. mit 

einem Durchgangsprüfer oder Multimeter). Mechanische 
Krafteinwirkungen beispielsweise während der Installation 
können das Glassgehäuse der Reed-Schalter beschädigen. 

Hinweis: 

Beachten Sie bei der Installation des Kontakts, dass 

sich die Türen unter Temperatureinfluss verziehen können. 

Schaltplan 

Legende Abbildung 3 

Farbe 

Bezeichnung 

(1)  2X Kupfer 

Sabotage-

, Überwachungsleitung 

(2)  2X Silber 

Alarm, normalerweise geschlossen (DC107, 
DC107S60) 

(3)  2X Silber 

Alarm, normalerweise geschlossen (DC107R4.7) 

Packungsinhalt 

• 

1X Magnetkontakt 

Ø24 x 28,6 mm 

• 

1X Magnet 

Ø24 x 39,7 mm 

Technische Daten 

Kabellänge: 
 

DC107, DC107R4.7 

 

DC107S60 

 
2,5 m 
6 m 

Schalter-Widerstand geschlossen: 
 

DC107, DC107S60 

 

DC107R4.7 

 
< 2 

Ω 

4,7 

kΩ ±10 % 

Schalter-Widerstand offen: 
 

DC107, DC107S60 

 

DC107R4.7 

 

10 MΩ 

9,4 

kΩ ± 10% 

Befestigung auf ferromagnetischem Material 

Annäherungsabstand Y (Schalter geschlossen) 

13 mm ±25 % 

Entfernungsabstand Y (Schalter offen) 

15 mm ±25 % 

Annäherungsabstand Z (Schalter geschlossen) 

10 mm ±35% 

Entfernungsabstand Z (Schalter offen) 

12 mm ±35% 

Kontakttyp 

Schließer 

Summary of Contents for DC107 Series

Page 1: ... mechanical force for example when installing can damage the glass body of the reed switches Note When installing the contact please keep in mind that the doors can bend under temperature influence UTC recommends to check regularly that the magnetic contact is working properly on the control panel and that the installers advise their customers to do this Wiring description Figure 3 legend Colour D...

Page 2: ... eu recycle Contact information www utcfireandsecurity com or www interlogix com For customer support see www utcfssecurityproducts eu DE Installationsanleitung Bezeichnung Bei der DC107 Serie handelt es sich um Magnetkontakte für die Einbaumontage die mit einer Einbruchmeldeanlage verbunden werden können Die DC107 Serie kann in ferromagnetischen Umgebungen verwendet und in Türen eingebaut werden ...

Page 3: ...hierzu finden Sie auf der folgenden Website www utcfssecurityproducts eu recycle Kontaktinformationen www utcfireandsecurity com oder www interlogix com Kontaktinformationen für den Kundendienst finden Sie unter www utcfssecurityproducts de ES Hoja de instalación Descripción La contactos de la serie DC107 son contactos magnéticos de montaje empotrado que se pueden conectar a un sistema de alarma a...

Page 4: ...ner más información consulte www utcfssecurityproducts eu recycle Información de contacto www utcfireandsecurity com o www interlogix com Para acceder al servicio técnico consulte www utcfssecurityproducts es FR Fiche d installation Description La gamme DC107 est constituée de contacts magnétiques montés en surface pouvant être connectés à un système d alarme intrusion Ils peuvent être utilisés da...

Page 5: ...cle Informations de contact www utcfireandsecurity com ou www interlogix com Pour contacter l assistance clientèle voir www utcfssecurityproducts fr mail_support htm IT Istruzioni per l installazione Descrizione I contatti magnetici per montaggio a incasso serie DC107 possono essere collegati a un sistema di allarme anti intrusione Possono inoltre essere utilizzati su porte e ambienti ferromagneti...

Page 6: ...te oppure rivolgervi e consegnarli presso i centri di raccolta preposti Per maggiori informazioni vedere www utcfssecurityproducts eu recycle Informazioni di contatto www utcfireandsecurity com o www interlogix com Per l assistenza clienti vedere www utcfssecurityproducts it NL Installatieblad Beschrijving De DC107 serie bestaat uit inbouw magnetische contacten die kunnen worden aangesloten op een...

Page 7: ...erzamelpunt Meer informatie vindt u op de volgende website www utcfssecurityproducts eu recycle Contactgegevens www utcfireandsecurity com of www interlogix com Voor klantenondersteuning zie www utcfssecurityproducts nl PL Instrukcja instalacji Opis Seria DC107 to wpuszczane czujki magnetyczne które można podłączyć do systemu alarmowego antywłamaniowego Czujki serii DC107 można stosować na materia...

Page 8: ...z www utcfssecurityproducts eu recycle Informacje kontaktowe www utcfireandsecurity com lub www interlogix com Informacje na temat pomocy technicznej można znaleźć na stronie www utcfssecurityproducts pl PT Ficha de Instalação Descrição A série DC107 é composta por contactos magnéticos para montagem embutida que podem ser ligados a um sistema de alarme anti roubo A série DC107 pode ser utilizada e...

Page 9: ...ando da compra de um novo equipamento equivalente ou coloque o num ponto de recolha designado para o efeito Para mais informações consulte www utcfssecurityproducts eu recycle Informação de contacto www utcfireandsecurity com ou www interlogix com Para assistência ao cliente consulte www utcfssecurityproducts eu SV Installationsanvisning Beskrivning DC107 serien innehåller ytmonterade magnetkontak...

Page 10: ... om garantifriskrivningar och produktsäkerhet se https firesecurityproducts com policy product warning eller skanna QR koden Certifiering EN 50131 EN 50131 2 6 2008 Security Grade 2 Environmental class II Kontrollerad av Applica Test Certification Norge Intygad av SBSC Sverige SBSC SSF1014 4 Larmklass 2 Klass II Intygad av SBSC Sverige EU direktiv UTC Fire Security meddelar harmed att denna produc...

Reviews: