Appendix B: Reference Tables
Table B1: Sensor Group Characteristics
No.
Name
Application
Alarm
Delay
Resto
ral
S
upe
rv
is
or
y
CS
R
e
p
o
rt
Ch
im
e
Active
Levels
00
Fixed Panic
24-hour audible fixed emergency buttons.
Police
Instant
√ √
1, 2, 3
01
Portable Panic
24-hour audible portable emergency buttons.
Police
Instant
√
1, 2, 3
02
Fixed Panic
24-hour silent fixed emergency buttons.
Silent
Instant
√ √
1, 2, 3
03
Portable Panic
24-hour silent portable emergency buttons.
Silent
Instant
√
1, 2, 3
04
Fixed Emergency
24-hour emergency sensor, such as Pendant Panic or
holdup button.
Emergency Instant
√ √
1, 2, 3
06
Portable
Emergency
24-hour portable emergency alert button.
Emergency Instant
√
1, 2, 3
08
Special Intrusion
Special belongings, such as gun cabinets and wall
safes.
Police
Instant
√ √ √
1, 2, 3
09
Special Intrusion
Special belongings, such as gun cabinets and wall
safes.
Police
Standard
√ √ √
1, 2, 3
10
Entry/Exit Delay
Entry and exit doors that require a standard delay time. Police
Standard
√ √ √ √
2, 3
13
Instant Perimeter
Exterior doors and windows.
Police
Instant
√ √ √
2, 3
14
Instant Interior
Interior doors.
Police
Follower
√ √ √
2, 3
15
Instant Interior
Interior PIR motion sensors.
*
Police
Follower
√ √
2, 3
16
Instant Interior
Interior doors.
Police
Follower
√ √ √
3
17
Instant Interior
PIR motion sensors.
*
Police
Follower
√ √
3
18
Instant Interior
PIR motion sensors subject to false alarms.
*
†
Police
Follower
√ √
3
19
Delayed Interior
Interior doors that initiate a delay before going into
alarm.
*
Police
Standard
√ √ √
3
20
Delayed Interior
PIR motion sensors that initiate a delay before going
into alarm.
*
Police
Standard
√ √
3
21
Local Instant
Interior
24-hour local alarm zone protecting anything that
opens and closes.
Police
Instant
√ √
1, 2, 3
22
Local Delayed
Interior
Same as group 21, plus activation initiates a delay
before going into alarm.
Police
Standard
√ √
1, 2, 3
23
Local Instant
Emergency
24-hour local alarm zone protecting anything that
opens and closes. ‡
Emergency Instant
√ √
1, 2, 3
25
Local Special
Chime
Notify the user when a door is opened. Sounds emit
from a local annunciator.
*
Note
If using a PIR motion sensor, use only ITI part no.
60-511-01-95.
Special
Chime
Instant
√
1, 2, 3
26
Fire
24-hour fire, rate-of-rise heat, and smoke sensors.
Fire
Instant
√ √ √
1, 2, 3
34
Gas
Carbonmonoxide (CO) Gas Detectors
‡
Emergency Instant
√ √ √
1, 2, 3
36
DTIM
Dialog Telephone Interface Module (DTIM)
a
Police
Instant
√ √
1, 2, 3