VALVE
NO.
AUX
NO.
" "
" "
" ".
0 long time working for
water pump
1 water pump turns off
after the whole unit power
off for 30s
initialization 0
5.2 The functions of controller display
1
2
MIN
TEMP
ON
OFF
%
h
%
C F
C F
AUTO
h
MIN
IN
SET
VALVE
OUT
ROOM
NO.
HUM
FAN
Initialisation
Press to turn
on and turn off
the units.
Press button to
change modes press 10
S
to set operation parameter
under stand by status,or
check the operation
parameter under running
or stand by status.
M
Press button 5S to set
clock.
SET
Press 5S to set
Timer ON/OFF
C
ROOM
S
tand by
status
The LCD display shows the
room temperature and the
current mode.
C
NO.
Parameter 01
to set inlet water temp.under
heating mode (15-40 )default
setting:40
℃
℃
S
etting operation parameter
Under standby status,press M button 10s to enter Operation Parameter setting interface;
Press M again to start setting (parameter from 00-D,see the Operation Parameter Table);
Under parameter setting,press
or
to set data;
Please note no motion on the display for 10s,the LCD will display water-in/water out temp.(under running)or
ambient temp.(under standby status)
Under running status,you can press M 10 to check current parameter,but can not change data of parameter!
" "
" ”
"
"
s
Remarks:Standby status means the unit is connected with electricity but not running.
NO.
Parameter 08
Mode:
1(cooling&heating)
2auxiliary elec heating
(heating)
3(heating only)
11
EN