16
2. THRESHOLD B
–
(THS-B) (BIAS)
Setting range 1-99
Factory preset at 50
Navigating to Threshold B
Select Menu Option #2, then press the
button to open the
Threshold B setting.
YouTube Reference
•
to see how to set Threshold B.
Threshold B Neutral Position
When looking for both rising and falling pitch targets it's best to put
THRESHOLD B in the neutral position (around 50) and raise
THRESHOLD A to create your desired threshold level.
Locating the “Neutral Position” is determined by raising and lowering
Threshold B and taking note of the numbers as per the following
procedure:
•
Start by raising THRESHOLD B with the
button until the
THRESHOLD B starts to get to a tolerable volume level (e.g.
58).
•
Then lower THRESHOLD B with the
button until you get
the same volume level e.g. 44.
o
The above example range is 58 less 44 = 14.
o
Halve the 14, which becomes 7.
o
Add 7 to 44 = 51.
•
51 is then the THRESHOLD B neutral Position in this example.
YouTube Reference
•
to see how to set Threshold B to
Neutral
Summary of Contents for QED-PL2