2.1.6
SERDES (QLMs)
The CN78XX has eight Quad Lane Modules (QLM), with each consisting of Four
SERDES that can be configured as different interfaces, such as SGMII, XAUI, RXAUI,
XFI/KR, XLAUI, or PCI-e.
The TAHOE 8724 QLMs are configured as follows:
a)
QLM0 – PCI-e 3.0 x4
b)
QLM1 – SGMII x1
c)
QLM2 – RXAUI x2
d)
QLM3 – RXAUI x2
e)
QLM4 – XFI/KR x4 or XLAUI x1
f)
QLM5 – XFI/KR x4 or XLAUI x1
g)
QLM6 – XFI/KR x4 or XLAUI x1
h)
QLM7 – XFI/KR x4 or XLAUI x1
a.
QLM0 is configured as PIC-e 3.0 RC interface to connect with PEX8724 PCI-e
switch.
b.
QLM1 is configured as SGMII interface to connect with a GE PHY VSC8221 to
provide the management port.
c.
QLM2/3 is configured as RXAUI interface to connect with CS4318 Quad RAXUI
to SFI PHY to provide four SFP+ ports.
d.
QLM4/5/6/7 is configured as XFI or XLAUI interface to connect with the PHY on
the IO module.