2 TECHNICAL SPECIFICATION 

Size 

Length: 

 

 

255 mm 

Width:  

 

            219 mm 

Height: 

 

            100 mm 

Weight: 

 

            1,77 kg 

 
 

 

 

 

      EU   

 

 

              US 

Voltage: 

 

    230 V 

 

 

 

115 V 

Frequency: 

 

    50 Hz 

 

 

 

60 Hz 

Taking away power:       36 W 

 

 

 

36 W 

 

Influence on environment 

Temperature   

             5 °C - 40 °C 

Relative air humidity    

90 % at 20 °C 

 

Plate with labels and data with specification, serial number and CE sign is on the back of the 
instrument. 

Summary of Contents for INTERLUX

Page 1: ...INTERDENT D O O Opekarni ka cesta 26 3000 Celje Slovenija Tel 386 3 425 62 00 Fax 386 3 425 62 10 Email info interdent cc www interdent cc Instruction for use INTERLUX...

Page 2: ...IONS FOR SAFE WORK 5 5 ELECTRIC OPERATIVE RELIABILITY 5 6 SAFETY USAGE 6 7 SETTING AND STARTING 6 8 PLACING 6 9 STARTING 7 10 MAINTAINCE 7 11 CLEANING AND CARE 8 12 DISTURBANCES AND THEIR RESOLVING 9...

Page 3: ...3 1 VOLUME OF SUPPLY PART DESCRIPTION 1 Casing 2 Polymerisation chamber 3 4 fluorescent lamps 4 Lattice switch 5 Lattice cable 6 Fuse 7 Switch for choosing the method of work 8 Start switch Art t 0715...

Page 4: ...Weight 1 77 kg EU US Voltage 230 V 115 V Frequency 50 Hz 60 Hz Taking away power 36 W 36 W Influence on environment Temperature 5 C 40 C Relative air humidity 90 at 20 C Plate with labels and data wit...

Page 5: ...ions should be taken under consideration INTERLUX is used exclusively for photopolymerisation of lacquers and synthetic plastic materials which are light consolidating Usage for other purposes is not...

Page 6: ...revented until the instrument is not flawless To prevent unwanted polymerisation you should not put synthetic materials which can be polymerised by light in front of the instrument 7 SETTING AND START...

Page 7: ...will be turned on for requested duration Damaged fluorescent bulbs should be immediately changed The instrument should not be operating with damaged bulbs In case that one or more fluorescent bulbs do...

Page 8: ...RE Before each cleaning the instrument should be turned off You should be careful that there are not any leftovers of materials in the polymerisation chamber It is recommended that you clean the lefto...

Page 9: ...set the fuse reconnect call maintance One or more hose does not shine Hoses are not inserted correclty Check hoses and insert them correctly Damaged hose Insert new hoses Polymerisation takes too lon...

Page 10: ...o Opekarni ka cesta 26 SI 3000 CELJE Was developed constructed and made in accordance with following demands EU directive for instruments 98 37 EU EU directive for low voltage 73 23 EWG changed in 93...

Page 11: ...he warranty period Failure will be resolved free of charge within 45 days from the date of failure report The product which will not be repaired within this deadline will be at your request replaced w...

Reviews: