Intercoax ECP-2808RM User Manual Download Page 7

Hardware Installation — 7

2.3.  LED Indication

2

2

1

3 4

6

5

3 4

6

5

2

[EUP-2816RM]

[ECP-2816RM]

[EUP-2808RM]

[ECP-2808RM]

2

1

3 4

6

5

3 4

6

5

No.

LED 

Indication

On

Off

Blinking

1

B-Linx/T-Linx

(1~8 / 1~16)

•  ECP/EUP Transmitter is 

connected 

•  Power over coax / UTP 

working properly

•  No device connected 

on B-Linx / T-Linx port

•  Short circuit or over current 

protection is working 

2

Join

(1~4 / 5~8,  

9~12, 13~16)

•  Unjoined ECP device is 

connected

•  ECP/EUP transmitter linked 

properly

•  Transmitting Data Via  

Coax / UTP

3

Alarm

•  System boot-up

•  Alarm is detected

•  Device in normal operation 

•  Factory reset is progressing

4

SFP

•  Transmitting Data

•  SFP Link is down

•  No device connected on 

SFP port

5

LINK

•  Uplink (Copper) is down

•  Transmitting Data 

Green: 10/100  
Amber: 1000

6

PWR

•  Power ON

•  Power OFF

Summary of Contents for ECP-2808RM

Page 1: ...User Manual Hardware www intercoax com Ethernet over Coax UTP Managed Receiving Switch ECP 2808RM ECP 2816RM EUP 2808RM EUP 2816RM Rev 3 0...

Page 2: ...rials 8 2 4 2 Hardware Installation 8 2 4 2 1 Rackmount Bracket Installation Guide 2 4 2 2 Rack Mount Instructions 2 4 2 3 Grounding 2 4 3 Joining instruction 15 2 4 4 Label the configured network gro...

Page 3: ...ong time i e Connecting analog camera to BNC connector Do not connect analog cameras to BNC connectors B Linx Port on this devices ECP Series only Do not connect any IP devices to RJ45 connectors T Li...

Page 4: ...vices remotely 1 2 Features Ethernet PoE transmission over Coax UTP cable Complies to IEEE1901 HPAV standard Extended transmission distance up to 2 400m PoE PoE Extra PoE up to 60W PoE per B Linx port...

Page 5: ...816RM ECP 2808RM 2 5 6 7 8 3 4 EUP 2808RM No Description 1 B Linx Ports 1 8 1 16 Connect Intercoax ECP Transmitters or IEEE1901 HPAV standard devices by coaxial cable with BNC male connector 2 T Linx...

Page 6: ...Press the button with a paper clip and hold for 2 seconds for Joining Create new password Press the button with a paper clip and hold for 15 seconds for Unjoining Remove the existing password Note Ple...

Page 7: ...nected on B Linx T Linx port Short circuit or over current protection is working 2 Join 1 4 5 8 9 12 13 16 Unjoined ECP device is connected ECP EUP transmitter linked properly Transmitting Data Via Co...

Page 8: ...atch cord Short Coax cable or 4 pairs UTP cable at least 4 cables for joining Password label if it is necessary Paper clip If it is necessary for pressing joining button Network Switch and PC OS Windo...

Page 9: ...ay configuration between ECP EUP Series 6 If the green Join LED is OFF on both receiving switch and ECP Transmitter joining work should be necessary for network communication Note For joining work Ple...

Page 10: ...temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperatu...

Page 11: ...DG DG DC Ground Product PCB Board The outside of BNC connector A Main Unit AC Power input product ex ECP 2808 E Earth FG Frame ground AC power input Product Case B AC Power Input Concentric plug ex I...

Page 12: ...n 12 Earth and FG link A B C Right example B AC Power input must be connected A terminal AC powered product and C set rack type case Incorrect example X X X X When Xpart no connections failure such as...

Page 13: ...nect FG and DG directly Right example ex ECP 8404 Product Case FG c ex ECP 8404 is FG Frame Ground is Protection element is DG DC Ground c d e d c e Product PCB board DG e d d d d c e When need protec...

Page 14: ...ach other Incorrect example Failure Noise Failure Short circuit ECP 2704T ECP 2701 ECP 2701 ECP 2701 ex ECP 2816RM ex ECP 2816RM ECP 2704T ECP 2701 ECP 2701 etc Be careful with Camera and Camera Power...

Page 15: ...B Linx port 1 to 4 and apply the power to the receiving switch 2 Unjoin If required when Join LED on both receiving switch and ECP Transmitter is not ON Removing the password A Push the join button fo...

Page 16: ...e also easily changed by Intercoax Manager software Please visit www intercoax com to download the software 2 4 4 Label the configured network group After joining with the join button it is highly rec...

Page 17: ...hen using ECP 9xxxx 8xxxx series as Transmitter Based on One transmitter per port RG6 Coaxial Cable 50m 100m 200m 300m 500m Trans Rate Mbps 21 2 21 2 21 1 21 1 21 PoE Output W 45 2 33 1 18 2 12 5 7 4...

Page 18: ...2 as Transmitter Based on One transmitter per port Cat 5e UTP Cable 50m 100m 200m 300m 500m Trans Rate Mbps 21 2 21 2 21 1 22 2 20 2 PoE Output W 51 7 45 4 28 1 21 3 12 6 Max Transmission rate Mbps me...

Page 19: ...as remote transmitters for the maximum performance Application Examples ECP 2816RM EoC PoC PoE Camera ECP 2704T Coax PoE Data AC 100 240V AC 100 240V NVR Network Switch ECP 2701 Coax Coax Coax ECP 270...

Page 20: ...P IGMP V1 V2 V3 Snooping IGMP Query Report Generator Data Transmission Distance Coax Up to 2 400m RG6 UTP Up to 1 200m Cat 5e Power Transmission Distance Coax Up to 1 200m RG6 7W UTP Up to 1 500m Cat...

Page 21: ...he cable length does not exceed transmission distance limitation e g 500 meters Please refer to Specification on 2 5 Transmission distance Bandwidth by distance Check the cable condition and ensure al...

Page 22: ...oduct and in no event shall Intercoax have any liability for any incidental consequential special or indirect damages 6 Regulatory and Certificates INFORMATION TO THE USER This equipment has been test...

Reviews: